EasyManuals Logo

LG LRMXC2206 Series Service Bulletin Booklet

LG LRMXC2206 Series
78 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #30 background imageLoading...
Page #30 background image
Defrost Heater Error (F dH)
1
Reconnect the
housing
Check the Main PCBA connect
Is Loose ?
Yes
No
2
Check the Defrost control part of Main PCB
Housing.
Is Sheath Heater resistance 35~40?
Yes
To step 4
4
Check the Heater Voltage is 110V ~ 120V?
No
3
No
Yes
Replace sheath
heater
Enter Test 3 mode
REF after running A period of time and then push
test button 3 times and show ’33 33’ in Display
PCB
Replace
Main PCB
NO
TEST MODE 3 Voltage [V]
CON3
2
nd
pin ~ 9
th
pin
110V ~ 120V
Yes
5
Explain to customer
Check the Defrost control part of Sheath
Heater Housing
Is Sheath Heater resistance 35~40?