11. Auto restarting operation
When the power is restarted after a sudden power failure while in appliance operation, the mode before the
power failure is kept on the memory and the appliance automatically operates in the mode on the memory.
The slide switch on the indoor unit of the appliance should be on the AUTO RESTART position in order that
the Auto restarting operation is available.
Operation mode that is kept on the memory
State of operation ON/OFF
Operation mode/setting temp./selected airflow speed
Sleep timer mode/remaining time of sleep timer
12. Forced operation
To operate the appliance by force in case that the remote control is lost, the forced operation selection switch
is on the main unit of the appliance to operate the appliance in the standard conditions.
The operation condition is set according to the outdoor temp. and intake air temperature as follows.
-23-
Outdoor temp.
over 24°C
21~24°C
18~21°C
below 18°C
Setting temp.
22°C
23°C
23°C
24°C
24°C
Setting speed of
indoor fan
High speed
Operating Mode
Cooling
Healthy Dehumidification
Intake air temp. 25°C Dehumidification
Intake air temp. < 25°C Heating
Heating
FORCED