-65-
The problem of missing the connector (INDOOR MAIN PCB ASSY)
Connectors
CN-POWER
(AC2)
CN-FAN
CN-DATA
CN-DISP1
CN-DISP2
CN-TH
CN-U/D
Condition
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN/SHORT
OPEN
Malfunctions all indoor & outdoor unit.
Malfunctions remocon, force, test operation mode.
Malfunctions outdoor unit.
Stop compressor and outdoor fan motor.
The operation LED blinks 5 times.
Communicaion error.
Malfunctions remote contoller.
Don't operate the power display module.
Don't operate the power display module.
(LS-_NM/NN Series is not included)
The operation LED blinks twice.
Enable to receive remote singnal.
Malfunctions UP/DOWN step motor.
Don't operate louver.
Malfunctions indoor fan motor.
Problem (error mode)