-26-
3) How to fix installation plate
The wall you select should be strong and solid enough to
prevent vibration
1. Mount the installation plate on the wall with 
6 type "A" screws. If mounting the unit on a con-
crete wall, use anchor bolts.
■ Mount the installation plate horizontally by aligning
the centerline using a level.
2. Measure the wall and mark the centerline. It is also
important to use caution concerning the location
of the installation plate-routing of the wiring to
power outlets is through the walls typically. Drilling
the hole through the wall for piping connections
must be done safely.
ABCD
7k, 9k 50 20 80 20
12k, 18k 45 40 80 20
CHASSIS
(Grade)
Distance (mm)
4) Drill a hole in the wall
■ Drill the piping hole with a ø70mm hole core drill.
Drill the piping hole at either the right or the left with
the hole slightly slanted to the outdoor side.