Remote Control Operation Mode
When the remote control is selected by the slide switch on the main unit, the appliance operates according to
the input by the remote controller.
Protection of the evaporator pipe from frosting
If the indoor pipe temp is below 0°C in 7 min after the compressor operates without any pause while in cooling
cycle operation mode, the compressor and the outdoor fan are turned off in order to protect the indoor evapora-
tor pipe from frosting.
When the indoor pipe temp is 7°C or higher after 3 min pause of the compressor, the compressor and the out-
door fan is turned on according to the condition of the room temperature.
Buzzer Sounding Operation
When the appliance-operation key is input by the remote controller, the short beep-beep- sounds.
When the appliance-pause key is input by the remote controller, the long beep—” sounds.
When a key is input by the remote controller while the slide switch on the main unit of the appliance is on the
forced operation position, the error sound beep-beep-beep-beep-beep- is made 10 times to indicate that the
remote control signal cannot be received.
Self Diagnosis Operation
Thermistor Error Indicator
When the indoor pipe sensor or the room temperature sensor is open or is shorted, the error is indicated.
To indicate the error, the operation LED (or the cooling LED) flashed at 3 sec interval.
When the error is cleared, the LED stops flashing, the operation (or cooling) LED is on.
While in appliance pause, the error is not indicated.
Since the airflow quantity and speed are controlled by the adjustment of the vane angle using the Wind-up
effect, you can enjoy the natural and pleasant wind uniformly at any location in the room.
Since the indoor outflow air is sucked again by the upper/lower vanes, the indoor temperature drop is mini-
mized and the pleasant humidity is maintained.
Air Cleaner Operation
When an air cleaner function is selected during Air Conditioner operation
- Plasma air cleaner function will be operated while in any operation mode with selecting the function.
- The function is to be stopped while it is operating with selecting the function.
When an air cleaner function is selected during operation off
- The function will be only operated.
When inlet grille of air conditioner is opened during plasma operation, High Voltage Generator(H.V.B) is to be
stopped. When inlet grille of air conditioner is closed during plasma operation, High Voltage Generator(H.V.B)
will be operated again.