22 Floor Standing Type Air Conditioner
Installation
Installation
Installation of Indoor, Outdoor Unit
1) Selection of the best location
Indoor unit
There should not be any heat source or steam
near the unit.
There should not be any obstacles to prevent the
air circulation.
A place where air circulation in the room will be
good.
A place where drainage can be easily obtained.
A place where noise prevention is taken into con-
sideration.
Do not install the unit near the door way.
Ensure the spaces indicated by arrows from the
wall, ceiling, fence, or other obstacles.
Outdoor unit
If an awning is built over the unit to prevent direct
sunlight or rain exposure, be careful that heat
radiation from the condenser is not restricted.
There should not be any animals or plants which
could be affected by discharged hot air.
Ensure the space indicated by arrows from the
wall, ceiling, fence, or other obstacles.
5cm
A
B
Indoor unit
Outdoor unit
50cm
50cm
50cm
150cm
5cm
40cm
100cm
Piping length and the elevation
1" 5/8" 50 35
80K
(Btu/h)
PIPE SIZE
MODEL
GAS SIDE LIQUID SIDE
Max.
Length
A (m)
Max.
Elevation
B (m)

Related product manuals