EasyManua.ls Logo

LG MS09SQ - User Manual

LG MS09SQ
23 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
P/NO : MFL67870308
www.lg.com
Please read this manual carefully before operating
your set and retain it for future reference.
WALL MOUNTED
Original instruction
OWNER’S MANUAL
AIR
CONDITIONER
[
Representative
]
LG Electronics Inc. EU Representative : LG Electronics European Shared Service Center B.V.
Krijgsman 1, 1186 DM Amstelveen, The Netherlands
[
Manufacturer
]
LG Electronics Inc. Changwon 2nd factory 84, Wanam-ro, Seongsan-gu, Changwon-si,
Gyeongsangnam-do, KOREA
ENGLISH
ITALIANO ESPAÑOL
FRANÇAIS
DEUTSCH
ΕΛΛΗΝΙΚΆ
ČEŠTINA
NEDERLANDS
POLSKI
LIMBA ROMÂNĂ
1,MFL67870308,영영 17. 7. 19. 영영 9:30 Page 1

Other manuals for LG MS09SQ

Questions and Answers

Overview

This document is an owner's manual for an LG wall-mounted air conditioner, designed to provide instructions for its safe and efficient operation, as well as maintenance.

Function Description

The LG air conditioner is designed to regulate indoor air temperature and quality. It offers several operational modes to suit different environmental needs:

  • Cooling Operation: This is the primary function for reducing indoor temperature. Users can set the desired temperature within a range of 18°C to 30°C.
  • Heating Operation: For models that support heating, this function raises the indoor temperature. The temperature range for heating is typically 16°C to 30°C.
  • Dehumidifying Operation: This mode is specifically designed to remove excess moisture from the air, which is particularly useful in humid environments or during rainy seasons. It automatically adjusts room temperature and fan speed to maintain optimal humidity levels, and the room temperature is not manually adjustable in this mode.
  • Air Circulation Operation: In this mode, the air conditioner circulates indoor air without actively cooling or heating it, helping to maintain air movement.
  • Auto Operation (Artificial Intelligence): This advanced function allows the air conditioner to automatically set the desired temperature and indoor fan speed based on artificial intelligence, with a temperature range of 18°C to 30°C.
  • Jet Cool/Heat Operation: This feature enables rapid cooling or heating of the indoor air. In jet cooling mode, strong air at 18°C is blown for 30 minutes, while in jet heating mode, strong air at 30°C is blown for 30 minutes. This function is not available in Air Circulation, Auto, or Auto Changeover modes.
  • Energy Saving Cooling Mode: This mode aims to minimize power consumption during cooling by increasing the set temperature to an optimal level for a more comfortable and energy-efficient environment.
  • Plasma Purification Operation: For models equipped with a plasma filter, this function removes microscopic contaminants from the intake air, providing clean and fresh air. It can be activated independently of other air conditioning functions.
  • Auto Clean Operation: After cooling or dehumidifying operations, moisture can accumulate inside the indoor unit. This function helps to remove such moisture, preventing mold growth. If the power is turned off, the fan will operate for 30 minutes to clean the indoor unit's interior.

Usage Features

The air conditioner is controlled primarily via a wireless remote control, which provides access to all its functions:

  • Remote Control Interface: The remote control features a display screen and a control panel with various buttons for different functions, including power on/off, mode selection, temperature adjustment, fan speed, air flow direction, timer settings, and special functions like Auto Clean, Energy Saving, and display brightness adjustment.
  • Temperature Adjustment: Dedicated buttons on the remote allow users to increase or decrease the room temperature.
  • Fan Speed Adjustment: The fan speed can be adjusted to circulate air more quickly or gently, with an option for natural air flow.
  • Air Flow Direction Adjustment: Users can adjust the vertical and, depending on the model, horizontal air flow direction to ensure even air distribution. An automatic adjustment option is also available.
  • Timer Function: This feature allows users to set specific times for the air conditioner to turn on or off automatically, contributing to energy saving and convenience. It requires setting the current time first.
  • Sleep Mode: When activated, this mode automatically turns off the air conditioner after a set period (up to 7 hours), adjusting the temperature for a more comfortable sleep. In cooling and dehumidifying modes, the temperature gradually increases by 1°C after 30 minutes and another 1°C after another 30 minutes, up to a total of 2°C from the preset temperature.
  • Display Screen Brightness: The brightness of the indoor unit's display screen can be adjusted using the remote control.
  • Operation Without Remote Control: In cases where the remote control is unavailable, the air conditioner can be operated using an On/Off button on the indoor unit. In this mode, the fan speed is automatically set to high.
  • Auto Restart Function: This is a factory default setting that restores the previous operational settings if the air conditioner is turned on again after a power failure. This function can be disabled or re-enabled by pressing and holding the On/Off button on the indoor unit for 6 seconds.

Maintenance Features

Regular maintenance is crucial for optimal performance and to prevent breakdowns. The manual outlines several cleaning procedures:

  • Air Filter Cleaning: The air filter should be cleaned every two weeks or more often if necessary. This involves turning off the power, unplugging the cord, opening the front grille, removing the filter, cleaning it with a vacuum cleaner or warm water (with detergent for stubborn dirt), and then drying it in the shade before reinserting.
  • 3M Filter Cleaning: The 3M filter should be cleaned once a month. Similar to the air filter, it requires power disconnection, opening the grille, removing the filter, and cleaning it with a vacuum cleaner. Washing with water is not recommended as it can damage the filter. It is suggested to change the 3M filter every 6 months.
  • Plasma Filter Cleaning: For models with a plasma filter, it should be cleaned every three months. The process involves turning off the power, unplugging the cord, opening the front grille, removing the air filter, then removing the plasma filter, cleaning it with a vacuum cleaner or lukewarm water (with detergent if needed), and drying it in the shade.
  • Indoor Unit Surface Cleaning: The indoor unit's surface should be cleaned regularly with a soft, dry cloth. Bleach or abrasives should not be used.
  • Outdoor Unit Cleaning: The heat exchanger coils and panel vents of the outdoor unit should be cleaned regularly, preferably with steam, by a technician. This helps maintain operational efficiency and prevent increased energy costs.
  • Safety Precautions for Maintenance: Before any maintenance, the power must be turned off and the power cord unplugged to prevent electric shock. Water hotter than 40°C or volatile substances should not be used on filters or surfaces to avoid deformation, discoloration, or damage to plastic parts.

The manual also includes a troubleshooting guide to help users identify and resolve common issues, such as abnormal operating conditions, the unit not working, mist discharge, water leaks, operating noise, or odors, before contacting service.

LG MS09SQ Specifications

General IconGeneral
Cooling Capacity9000 BTU/h
Power Supply220-240V, 50Hz
Indoor Unit Weight8.5 kg
TypeSplit System
Noise Level (Indoor)21 dB

Related product manuals