Functions Wired remote controllers
Function list
Premium Standard Simple
Category Level1 Level2 (Code) Level3 (Code) PREMTA000
PREMTB100
PREMTBB10
PREMTB001
PREMTBB01
PQRCVCL0Q/W
PQRCHCA0Q/W
Installer setting
Test run code : 01
Cooling (01:01)
Heating (01:02)
●●●●
Central control
address
code : 02
-
●●●●
ESP (fan RPM) code : 03
Slow (03:01:xxx)
Low (03:02:xxx)
Med (03:03:xxx)
High (03:04:xxx)
Pow (03:05:xxx)
●●●●
Thermistor code : 04
Remote controller
(04:01)
Indoor (04:02)
2TH (04:03)
●●●●
Ceiling height code : 05
Low (05:01)
Standard (05:02)
High (05:03)
Very high (05:04)
●●●●
RMC Master/slave code : 07
Slave (07:00)
Master (07:01)
●●●●
Override Master/Slave code : 08
Slave (08:00)
Master (08:01)
●●●
X
Dry contact mode code : 09
Manual (09:00)
Auto (09:01)
●●●
X
Fixed air volume code : 11
Variable (11:01)
Fixed (11:02)
●●●
X
Display temperature
unit
code : 12
Celsius (12:00)
Fahrenheit (12:01)
●
●
Refer to user setting
●●
Celcious temperature
unit
code : 17
1°C (17:00)
0.5°C. (17:01)
●
●
Refer to user setting
●●
Emergency heater
Not use Not use (18:00:0)
●●●
X
Use
Fan Off (18:01:xx:0)
Fan On (18:01:xx:1)
●●●
X
Function control during
group control
code : 19
Type 0 : Use common
functions (19:00)
Type 1 : Use expand-
ed functions (19:01)
●●●
X
Option Unit
Air purify
(code : 20)
Not installed (20:00)
Installed (20:01)
●●●
X
Heater (code : 21)
Not installed (21:00)
Installed (21:01)
●●●
X
Humidifier
(code : 22)
Not installed (22:00)
Installed (22:01)
●●●
X
Elevation grill
(code : 23)
Not installed (23:00)
Installed (23:01)
●●●
X
Ventilation kit
(code : 24)
Not installed (24:00)
Installed (24:01)
●●●
X
Aux Heater
(code : 25)
Step 0 : Not installed
(25:00)
Step 1 :
Installed (normal)
(25:01)
Step 2 : Installed (Duct)
(25:02)
●●●
X
Refrigerant leakage
detection sensor
(code : 29)
Not installed (29:00)
Installed (29:01)
●●●●