52
ERROR MODE / POWER FAIL RECOVERY / DEFAULT DRYER SETTINGS
PROBLEM POSSIBLE CAUSE SOLUTION
It is displayed when thermistor is open or short. Thermistor should be replaced
It is displayed when thermistor temperature
have increased about 17 degrees for
10 seconds
Thermistor should be replaced
It is displayed when blower fan motor is re-
strained.
Fan motor should be checked
It is displayed when thermistor temperature
have increased about 35 degrees from 5 to 10
minutes after starting.
Check the gas supply condition
Press reset switch during operating once and
then, check ignition operating
It is displayed when airow switch is open more
than 30 seconds When motor RPM is more than
600, It is displayed when airow switch is open
more than 20 seconds.
Check lint lter, exhaust duct, blower fan, and
front duct
It is displayed when airow switch is open for 3
seconds after starting.
Check air ow switch and drum motor
ERROR MODE
Meaning of Error Codes that LED displays during occurrence or problem.
Dryer error code
POWER FAIL RECOVERY
In case of power failure the machine stops running but the time display remains on, showing the time just before
power failure.
Press the Start button after the power is restored, then the machine will restart.
DEFAULT DRYER SETTINGS
Default Settings Default
Cycle Time (Minutes) 5 Minutes
Cool Down Time Cycle 2 Minutes
High Temperature 143.6° F (62° C)
Medium Temperature 131° F (55° C)
Low Temperature 116.6° F (47° C)
Top O Time (Minutes per coin) 5 Minutes
Coin #1 Value 25 ¢
Coin #2 Value 25 ¢
Minutes/Minutes and seconds Minutes
Temperature Unit Celsius
Error Mode On
MFL67863709_en_170328.indd 52 2017-03-28 �� 9:54:51