- 9 -
Note :
1) With the cable we have taken into account laying B2 from the table A.52.4 – IEC 60364-5-52. The cable in the installation pipe is fixed to the wall.
The dimensions of the electrical cables must always be checked or determined by the designing engineer of electrical installations.
2) Joint maximal load (circulation pumps, electronic valves ...) which can be connected to or powered by the internal unit, must not exceed the specified
value. Higher consumers (i.e. pumps) should have their own supply.
3) The circulation pump must be dimensioned in such a way that it ensures rated flow through the device.
4) This is true for pipe connections of suitable dimensions and joint distance of up to 20m. Pipe dimensions and types of pumps must always be verified or
determined by the designing engineer of electrical installations. Circulation pumps must be dimensioned in such a way so as to ensure rated voltage (see
table) through the device.
5) Connection to the internet is not necessary for the operation of the device but it is necessary for remote control through the Home Cloud service.
It is also advisable for faster troubleshooting of the device’s operation.
6) The size of the fuse depends on the choice of the connection power of the electrical heater.