INSTALLATION MANUAL
AIR-TO-WATER
HEAT PUMP
www.lg.com
Copyright © 2018 - 2022 LG Electronics Inc. All Rights Reserved.
MFL68026607
Rev.16_092722
Original instruction
Please read this installation manual completely before installing the
product.
Installation work must be performed in accordance with the national
wiring standards by authorized personnel only. Please retain this
installation manual for future reference after reading it thoroughly.
PORTUGUÊS
MAGYAR
БЪЛГАРСКИ
SRPSKI
HRVATSKI
SLOVENŠČINA
DANSK
ENGLISH
ITALIANO
ESPAÑOL
FRANÇAIS
DEUTSCH
ΕΛΛΗΝΙΚΆ
ČEŠTINA
NEDERLANDS
POLSKI
LIMBA ROMÂNĂ

Table of Contents

Questions and Answers

  • J
    Jacob OliverAug 12, 2025
    Why is my LG THERMA V HM141MR heating or cooling not satisfactory?
    • S
      Steven TurnerAug 12, 2025
      If your LG Heat Pump isn't heating or cooling properly, ensure the target temperature is set correctly, considering whether it's water-based or air-based. Also, check the pressure gauge and add water until it reads 2~2.5 Bar. Lastly, inspect the strainer for particle buildup and clean if necessary. Make sure the pressure gauge doesn't exceed 4 Bar and that the water pipe isn't blocked by particles or lime.
  • D
    David BassAug 18, 2025
    How to fix LG Heat Pump water pump noise?
    • A
      arroyodylanAug 19, 2025
      If your LG Heat Pump's water pump is making noise, it might be due to incomplete air purging. Open the air purge cap and add water until the pressure gauge reads 2~2.5 Bar. If water doesn't splash out when the tip is pressed, continue purging air. Also, check if the pressure gauge indicates above 0.3 Bar and verify the expansion tank and pressure gauge are functioning correctly.
  • T
    Terrance PerezAug 27, 2025
    What to do if LG THERMA V HM141MR Heat Pump does not start?
    • B
      Brian DawsonAug 27, 2025
      If your LG Heat Pump doesn't start even though the power supply is fine, it could be due to the water inlet temperature. The unit won't operate if the water inlet temperature exceeds 57 °C for system protection. Similarly, in cooling mode, it won't operate below 5 °C; allow the unit to warm the water. In heating mode, it won't operate below 15 °C; let it warm to 18 °C. If you're not using a back-up heater, increase the water temperature with an external heat source. If problems persist, contact your dealer. For screed drying, install back-up heater accessories.
  • O
    opittsSep 4, 2025
    What to do if water is flood out through drain hose in LG THERMA V HM141MR?
    • X
      xjonesSep 4, 2025
      If water floods out through the drain hose of your LG Heat Pump, it may be due to overfilling. Release water by opening the safety valve switch until the pressure gauge reads 2~2.5 Bar. Alternatively, the expansion tank might be damaged, requiring replacement. Finally, if the water tank heater's thermal protector is activated, open the DHW tank's side panel and press the reset button.

LG THERMA V HM141MR Specifications

General IconGeneral
TypeAir-to-Water Heat Pump
ModelHM141MR
Heating Capacity14 kW
RefrigerantR32
Sound Power Level65 dB(A)
Energy Efficiency Class (Heating)A++
Energy Efficiency Class (Cooling)A+
Operating Temperature Range (Heating)35°C
Dimensions (Outdoor Unit)950 mm