INSTALLATION MANUAL
AIR-TO-WATER
HEAT PUMP
www.lg.com
Please read this installation manual completely before installing the
product. Installation work must be performed in accordance with the
national wiring standards by authorized personnel only. Please retain
this installation manual for future reference after reading it thoroughly.
Original instruction
Copyright © 2017 - 2018 LG Electronics Inc. All Rights Reserved.
MFL68681810
Rev.04_062218
ENGLISH ITALIANO
ESPAÑOL
FRANÇAIS DEUTSCH
ΕΛΛΗΝΙΚΆ
ČEŠTINA
NEDERLANDS
POLSKI
LIMBA ROMÂNĂ

Table of Contents

Questions and Answers

  • G
    gonzalezginaAug 17, 2025
    Why is my LG Therma V AHUW096A3 Heat Pump heating or cooling poorly?
    • T
      tonyafieldsAug 17, 2025
      The unsatisfactory heating or cooling of your LG Heat Pump might be due to several reasons. First, the target temperature might not be set correctly; ensure it's properly adjusted and check if the temperature setting is water-based or air-based. Second, insufficient water charge could be the issue; inspect the pressure gauge and add water until it reads between 2 and 2.5 Bar. Lastly, a low water flow rate could be the cause; examine the strainer for particle buildup and clean it if necessary. Also, check if the pressure gauge indicates above 4 Bar, and inspect the water pipe for blockages from accumulated particles or lime.
  • S
    Stephanie MooreAug 20, 2025
    What to do if my LG Therma V AHUW096A3 Heat Pump water pump is noisy?
    • K
      kayla15Aug 20, 2025
      A noisy water pump in your LG Heat Pump could be due to air not being completely purged from the system or low water pressure. To resolve air issues, open the air purge cap and add water until the pressure gauge reads 2~2.5 Bar; if water doesn't splash out when the tip is pressed, purging isn't complete. To address low water pressure, check if the pressure gauge reads above 0.3 Bar and verify the expansion tank and pressure gauge are functioning correctly.
  • L
    luismccartyAug 23, 2025
    What to do if my LG Heat Pump isn't starting even with power?
    • L
      lopezjaredAug 23, 2025
      If your LG Heat Pump isn't starting despite having power, it could be due to the water inlet temperature being too high or too low. If the water inlet temperature exceeds 57 °C, the unit won't operate for system protection. Similarly, in cooling mode, the unit won't operate if the water inlet temperature is below 5 °C; allow the unit to warm up the water. In heating mode, operation is prevented if the temperature is below 15 °C; wait for it to reach 18 °C. If you're not using a backup heater, increase the water temperature with an external heat source. If the problem continues, contact your dealer. For screed drying, install backup heater accessories.
  • M
    Ms. Jamie Nichols PhDAug 26, 2025
    How to fix bad communication between the remote controller and LG Heat Pump unit?
    • R
      robinsonrobertAug 26, 2025
      Poor communication between the remote controller and the LG Heat Pump unit can stem from a few issues. Ensure the wire connection between the remote controller and the Main PCB assembly (Heater) is secure. Also, verify that the output voltage of the PCB is 12 V DC. The sensor might be faulty.
  • M
    Mary WalkerAug 28, 2025
    What to do if water is flooding from my LG Therma V AHUW096A3 Heat Pump's drain hose?
    • M
      Michelle MacdonaldAug 28, 2025
      If water is flooding out through the drain hose of your LG Heat Pump, it may be due to too much water being charged or a damaged expansion tank. To fix overcharging, release water by opening the safety valve switch until the pressure gauge reads 2~2.5 Bar. If the expansion tank is damaged, it should be replaced.
  • J
    jamesspencerAug 31, 2025
    How to troubleshoot a BLDC water pump lock on an LG Therma V AHUW096A3?
    • V
      valeriehoganAug 31, 2025
      A locked BLDC water pump in your LG Heat Pump can be caused by a restriction of the BLDC water pump, a defect or abnormal assembly condition of the BLDC Water pump, or a fan lock due to foreign material.
  • M
    Mrs. Jessica MclaughlinSep 2, 2025
    Why is my LG Therma V AHUW096A3 DHW not hot?
    • I
      Isaiah Grant Jr.Sep 2, 2025
      If the DHW (Domestic Hot Water) in your LG Heat Pump is not hot, it could be because the thermal protector of the water tank heater is activated. To resolve this, open the side panel of the DHW tank and push the reset button on the thermal protector. Another reason could be that DHW Heating is disabled. Make sure to select DHW Heating Operation and check if the icon is displayed on the remote controller.
  • B
    Bobby WolfeSep 5, 2025
    How to resolve bad communication between Main PCB assemblies in my LG Therma V AHUW096A3 Heat Pump?
    • J
      Joshua TorresSep 5, 2025
      Bad communication between the Main PCB assembly (Heater) and the Main PCB assembly (Inverter) in your LG Heat Pump can be caused by a disconnected connector for transmission. Ensure the wire connection between the remote control panel and the Main PCB assembly (Heater) is tight. The connecting wires may be misconnected, the communication line may be broken, or the Main PCB assembly(Inverter) or Main PCB assembly(Heater) may be abnormal.
  • D
    Danny WhiteSep 8, 2025
    What causes an LG Heat Pump water pipe to overheat?
    • J
      Jason RaySep 8, 2025
      An overheated water pipe in your LG Heat Pump can be caused by abnormal operation of the electric heater. If there is no problem in electric heater control, the maximum possible leaving water temperature is 57 °C.
  • J
    James LeeSep 12, 2025
    What causes a PCB program (EEPROM) fault in an LG Heat Pump?
    • T
      Tammy JonesSep 12, 2025
      A PCB program (EEPROM) fault in your LG Heat Pump can be caused by electrical or mechanical damage to the EEPROM. This error cannot be permitted.

Summary

System Overview and Safety Instructions

Manual Preface and Introduction

Introduction to the manual's purpose, structure, and general remarks.

Critical Safety Warnings and Precautions

Essential safety guidelines for installation, operation, and maintenance.

Installation and Configuration Procedures

Installation Parts and General Information

Details on unit components, model specifications, and general data.

Outdoor Unit Installation Procedures

Guidelines for outdoor unit placement, installation, and environmental considerations.

Indoor Unit Installation Procedures

Instructions for indoor unit placement, service space, and wall mounting.

Piping, Wiring, and Leakage Testing

Covers refrigerant, water piping, electrical wiring, and essential leak tests.

System Configuration and Settings

Configuration options including DIP switches, service, and installer settings.

Operation, Accessories, and Troubleshooting

Supported Accessories Installation

Information on installing and connecting various LG and third-party accessories.

Commissioning and Starting Operation

Pre-checks, operational flow, and initial startup procedures for the system.

Troubleshooting Common Problems

Guidance for diagnosing and resolving operational issues and error codes.

LG Therma V AHUW096A3 Specifications

General IconGeneral
BrandLG
ModelTherma V AHUW096A3
CategoryHeat Pump
LanguageEnglish