13
Single CAC Outdoor Unit
Compact Inverter
6. Capacity Tables
6.1 Models : AUUW18GC0 + ABNW18GBHC0
[UU18WC UL0] [UB18C NH0]
Cooling Capacity
• Rate of change in TC and PI due to the indoor unit at standard temperature condition.
Note
1. DB : Dry bulb temperature(), WB : Wet bulb temperature()
2. TC : Total capacity(kW), SHC : Sensible Heating Capacity(kW)
3. PI : Power Input (kW, Compressor + indoor fan motor + outdoor fan motor)
4. All capacities are net. A deduction (cooling mode) or an addition (heating mode) of Capacity due to operating heat of indoor unit motor is reflected.
5. Direct interpolation is permissible. Do not extrapolate.
6. Rated capacities and power inputs are based on standard temperature and piping conditions, and it can be found on specifications table. Except for
rated value, the performance is not guaranteed.
7. In accordance with the test standard(or nations), the rating will vary slightly.
Heating Capacity
• Rate of change in TC and PI due to the indoor unit at standard temperature condition.
Note
1. DB : Dry bulb temperature(), WB : Wet bulb temperature()
2. TC : Total capacity(kW), SHC : Sensible Heating Capacity(kW)
3. PI : Power Input (kW, Compressor + indoor fan motor + outdoor fan motor)
4. All capacities are net. A deduction (cooling mode) or an addition (heating mode) of Capacity due to operating heat of indoor unit motor is reflected.
5. Direct interpolation is permissible. Do not extrapolate.
6. Rated capacities and power inputs are based on standard temperature and piping conditions, and it can be found on specifications table. Except for
rated value, the performance is not guaranteed.
7. In accordance with the test standard(or nations), the rating will vary slightly.
Outdoor Air
Temp.
Indoor Air Temperature : °CDB / °CWB
20 / 14.0 22.0 / 16.0 25.0 / 18.0 27.0 / 19.0 30.0 / 22.0 32.0 / 24.0
°CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
20.0 3.30 2.92 0.78 4.13 3.44 1.03 4.76 3.95 1.28 5.24 4.21 1.33 5.72 4.13 1.37 6.08 4.08 1.38
25.0 3.12 2.83 0.85 3.95 3.35 1.11 4.58 3.86 1.38 5.06 4.12 1.43 5.54 4.05 1.48 5.90 4.00 1.49
32.0 2.87 2.71 0.97 3.70 3.23 1.23 4.33 3.74 1.52 4.81 4.00 1.57 5.29 3.93 1.62 5.65 3.88 1.63
35.0 2.76 2.66 1.02 3.59 3.18 1.28 4.22 3.69 1.58 4.70 3.95 1.63 5.18 3.87 1.68 5.54 3.82 1.69
40.0 2.58 2.57 1.11 3.41 3.09 1.37 3.64 3.25 1.33 4.07 3.47 1.37 4.50 3.40 1.41 4.82 3.36 1.41
43.0 2.47 2.47 1.16 3.30 3.04 1.42 3.29 2.97 1.17 3.69 3.18 1.21 4.09 3.12 1.24 4.39 3.08 1.25
46.0 2.36 2.36 1.21 3.19 2.99 1.47 2.94 2.69 1.02 3.31 2.89 1.05 3.67 2.83 1.08 3.95 2.79 1.08
48.0 2.29 2.29 1.24 3.12 2.95 1.50 2.71 2.50 0.92 3.06 2.69 0.94 3.40 2.63 0.97 3.66 2.60 0.97
Model
Correction factor
TC PI
AUUW18GC0 [UU18WC UL0]
Max. 1.09 1.15
Rated 1.00 1.00
Outdoor Air
Temp.
Indoor Air Temperature : °CDB
16.0 18.0 20.0 22.0 24.0
°CWB TC PI TC PI TC PI TC PI TC PI
-20.0 1.63 0.61 1.61 0.75 1.59 0.89 1.58 1.11 1.56 1.32
-15.0 2.53 0.89 2.51 1.03 2.50 1.17 2.48 1.36 2.46 1.55
-10.0 3.43 1.17 3.42 1.31 3.40 1.45 3.38 1.61 3.37 1.78
-5.0 4.33 1.45 4.32 1.59 4.30 1.73 4.28 1.86 4.27 2.00
0.0 5.24 1.73 5.22 1.86 5.20 2.00 4.99 1.89 4.78 1.78
6.0 5.76 1.84 5.48 1.75 5.20 1.67 4.99 1.59 4.78 1.50
10.0 5.76 1.73 5.48 1.59 5.20 1.45 4.99 1.38 4.78 1.32
15.0 5.76 1.45 5.48 1.31 5.20 1.17 4.99 1.13 4.78 1.09
18.0 5.76 1.28 5.48 1.14 5.20 1.00 4.99 0.98 4.78 0.96
Model
Correction factor
TC PI
AUUW18GC0 [UU18WC UL0]
Max. 1.10 1.15
Rated 1.00 1.00