EasyManua.ls Logo

LG UU36W UO2 - Specifications

LG UU36W UO2
158 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8
Single CAC Outdoor Unit
Standard Inverter
2. Specifications
Combinational Specifiactions
1 Phase Inverter
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power levIndoorel is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions :
*Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
*Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
Interconnected Pipe is standard length and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. This product contains Fluorinated greenhouse gases.
Combination
Outdoor unit
AUUW09GA0
[UU09W UL0]
AUUW09GA0
[UU09W UL0]
Indoor unit
ATNH09GRLE2
[CT09 NR2]
ABNW09GL2A2
[CB09L N22]
Capacity
Cooling
Min.~Rated~Max. kW 1.00 ~ 2.50 ~ 2.75 1.10 ~ 2.50 ~ 2.90
Min.~Rated~Max. Btu/h 3,400 ~ 8,500 ~ 9,400 3,800 ~ 8,500 ~ 9,900
Heating
Min.~Rated~Max. kW 1.20 ~ 3.00 ~ 3.30 1.20 ~ 3.20 ~ 3.60
Min.~Rated~Max. Btu/h 4,100 ~ 10,200 ~ 11,300 4,100 ~ 10,900 ~ 12,300
Power Input
Cooling Rated kW 0.625 0.660
Heating Rated kW 0.800 0.800
Running Current
Cooling Rated A 2.70 2.90
Heating Rated A 3.50 3.50
SEER / SCOP Wh / Wh 6.44 / 4.00 6.28 / 4.00
Seasonal Energy Label
(A++ to E Scale)
Cooling / Heating - A++ / A+ A++ / A+
Annual Energy Consumption Cooling / Heating kWh 136 / 980 139 / 1,050
Combination
Outdoor unit
AUUW09GA0
[UU09W UL0]
AUUW09GA0
[UU09W UL0]
Indoor unit
AVNH09GELA2
[CV09 NE2]
AQNH09GALA0
[CQ09 NA0]
Capacity
Cooling
Min.~Rated~Max. kW 1.00 ~ 2.50 ~ 2.75 1.30 ~ 2.55 ~ 2.80
Min.~Rated~Max. Btu/h 3,400 ~ 8,500 ~ 9,400 4,400 ~ 8,700 ~ 9,600
Heating
Min.~Rated~Max. kW 1.20 ~ 3.00 ~ 3.30 1.36 ~ 3.10 ~ 3.40
Min.~Rated~Max. Btu/h 4,100 ~ 10,200 ~ 11,300 4,600 ~ 10,600 ~ 11,600
Power Input
Cooling Rated kW 0.700 0.700
Heating Rated kW 0.830 0.840
Running Current
Cooling Rated A 3.10 3.10
Heating Rated A 3.60 3.70
SEER / SCOP Wh / Wh 5.87 / 3.81 5.60 / 3.81
Seasonal Energy Label
(A++ to E Scale)
Cooling / Heating - A+ / A A+ / A
Annual Energy Consumption Cooling / Heating kWh 149 / 1,029 159 / 1,029

Related product manuals