Single CAC Outdoor Unit
2. Specifications
16
Standard Inverter
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power levIndoorel is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions :
*Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
*Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
Interconnected Pipe is standard length and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. This product contains Fluorinated greenhouse gases.
Combination
Outdoor unit
AUUW606D2
[UU60W U32]
AUUW606D2
[UU60W U32]
Indoor unit
ATNH60GMLE2
[UT60 NM2]
ABNW60GM3A0
[UM60 N34]
Capacity
Cooling
Min.~Rated~Max. kW 5.92 ~ 14.6 ~ 16.3 5.90 ~ 15.0 ~ 16.3
Min.~Rated~Max. Btu/h 20,200 ~ 49,800 ~ 55,600 20,100 ~ 51,200 ~ 55,600
Heating
Min.~Rated~Max. kW 6.80 ~ 16.9 ~ 18.7 6.80 ~ 16.8 ~ 18.7
Min.~Rated~Max. Btu/h 23,200 ~ 57,700 ~ 63,800 23,200 ~ 57,300 ~ 63,800
Power Input
Cooling Rated kW 5.40 4.53
Heating Rated kW 5.50 4.79
Running Current
Cooling Rated A 23.50 19.1
Heating Rated A 23.90 20.2
SEER / SCOP Wh / Wh - - / -
Seasonal Energy Label
(A++ to E Scale)
Cooling / Heating - - - / -
Annual Energy Consumption Cooling / Heating kWh - - / -
Combination
Outdoor unit
AUUW606D2
[UU60W U32]
Indoor unit
UVNH60GLLA2
[UV60 NL2]
Capacity
Cooling
Min.~Rated~Max. kW 5.72 ~ 14.4 ~ 15.7
Min.~Rated~Max. Btu/h 19,500 ~ 49,100 ~ 53,600
Heating
Min.~Rated~Max. kW 6.80 ~ 16.8 ~ 18.7
Min.~Rated~Max. Btu/h 23,200 ~ 57,300 ~ 63,800
Power Input
Cooling Rated kW 5.24
Heating Rated kW 5.42
Running Current
Cooling Rated A 22.80
Heating Rated A 23.60
SEER / SCOP Wh / Wh -
Seasonal Energy Label
(A++ to E Scale)
Cooling / Heating - -
Annual Energy Consumption Cooling / Heating kWh -