EasyManua.ls Logo

LG WM2901H*A Series - Locked Motor Error

LG WM2901H*A Series
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
29
LOCKED MOTOR ERROR
Is displayed?
Check the connectors below.
Is the connector disconnected
or disassembled?
(motor hall sensor connector,
motor drive connector.)
- part of main PWB
assembly (NA1, RD4)
Reconnect
the connector.
(connector /
wire / motor )
Replace
the ROTOR.
Yes
Yes
Motor Drive
Is rotor magnet cracked?
Hall sensor
Motor Drive Hall Sensor
- part of wire
- part of motor
Motor
Yes
No
Yes
Yes
Magnet
Replace
the STATOR.
Is the resistance values
in the range of 5 to 15 ?
(U-V, V-W, W-V
:U=1, V=2, W=3)
-After pull out the RD4
connector, check the
terminal of the connector
in wire. (Red 3P, male)
No
Replace
the Hall
sensor.
Is hall sensor out of
order? (Refer to 9-3
Stator assembly/Hall
sensor.)
Yes
No
Replace the
MAIN PWB
ASSEMBLY.
Check the IPM in the
controller.
No