57
Moreover, the conditions that actuate this alarm also depend on the settings
of the “AO-Adv.Options” parameter (see chapter 4.2.8).
6.2.2 Motor Alarms
When these alarms are actuated, the SPIN will immediately power OFF the
motor. They can only be reset by switching off the device (see chapter 5).
If the cause that actuated the alarm has not been removed upon turning on
the unit again, the alarm will be actuated again. In this case, send the accu-
mulator to an LGL customer service point.
− “I Max”: Maximum overcurrent error detected within the motor.
− “Motor Lock”: Motor lock error. This message is displayed when the
accumulator cannot move the yarn feeding wheel although a strong
current is fed into the motor. Ensure the yarn is not jammed is not caught
between the spool and the accumulator input.
− “I Calib”: Motor current offset calibration error.
− “Hall Sens”: Motor Hall sensor reading error.
− “Fuse”: Fuse activation error. The internal fuse is electrically open or
blown.If this is the case, please send the unit to an LGL Customer
Service point.
− “V Low”: Low voltage error. The SPIN power supply voltage is LOWER
than the minimum voltage allowed. Check supply voltages (chapter 2.2).
− “V High”:High Voltage Error. The SPIN power supply voltage is HIGHER
than the maximum voltage allowed. Check supply voltages (chapter 2.2).
− “Temp High”: Motor temperature/overheating error.
− “Motor Cal”: Motor calibration error.
6.2.3 Cell Alarms
When these alarms are actuated, the SPIN will immediately power OFF the
motor. They can only be reset by switching off the device (see chapter 5).
If the cause that actuated the alarm has not been removed upon turning on
the unit again, the alarm will be actuated again. In this case, send the accu-
mulator to an LGL customer service point.
− “OFS Cell”: Cell Offset calibration error. Check the Offset (see procedure
in chapter 3.3)
− “GDN Cell”: Cell gain calibration error.
− “VRef Cell”:Cell reference threshold error.
− “Ack Cell”: Cell acknowledgement error.
− “ReadAvCell”: Cell signal average calculation error.
6 - MESSAGES AND ALARMS