Reduced Driving Speed Test
1) Raise the platform.
2) Press and hold the enabling switch on the
control handle.
3) Slowly move the control handle up to the
full driving position.
Result: When the platform is raised, the
maximum driving speed shall not exceed
1.1Km/h.
When the platform is raised, the maximum
driving speed of SR1018D/SR1218D shall not
exceed 0.5Km/h.
If the maximum driving speed exceeds 1.1Km/h
when the platform is raised, please tag out the
machine immediately and stop operating it.
8.6 Tilt Sensor Operation
Test
△
!
Notice: The test is performed from
the ground with a remote Platform
Control Station. Do not stand inside
the platform.
1) Lower the platform completely.
2) Drive two wheels on one side to an
obstacle or curb with height of 0.18m/0.59ft.
3) Raise the platform to a height which is
about 3.6m off of the ground.
Result: The platform is stopped and the tilt
alarm sounds 180 times per minute. The
indicator of enabling button of lifting function will
be in red.
4) Move the drive control handle in the
direction indicated by the blue arrow, and
move it to the direction indicated by the
yellow arrow.
Result: The drive function shall not work in
either direction.
5) Lower the platform and drive the machine
away from the obstacle.
8.7 Upper Limit Switch and
Outriggers (If Equipped) Test
1) Press and hold the enabling button with
lifting functions. Raise the platform.
Result: The platform of SR1023D/ SR1323D
/SR1623D shall be raised to 8.5m and then
stopped. The platform shall not be raised more
than 8.5m unless the outrigger has been
extend.
2) Lower the platform.
3) Press and hold the automatic leveling
button.
4) Move the control handle to the backward
direction.
Result: The outrigger shall be stretched out to
level the machine. When the machine is level, it
will sound.
5) Raise the platform.
Result: The platform shall be raised to the
highest point.
6) Lower the platform.