©Copyright 2012 Liberty Pumps Inc. All rights reserved
IMPORTANT:
Prior to installation, record Model, Serial Number, and
Code Number from pump nameplate for future reference.
MODEL ________________________
SERIAL ______________________
CODE ______________________
INSTALLATION
DATE _______________________
*Do not throw away or lose this manual.
7000 Apple Tree Avenue
Bergen, NY 14416
Phone: (800) 543-2550
Fax: (585) 494-1839
www.libertypumps.com
Contents
General Information
Dewatering/Sump Applications
Effluent Applications
Electrical Service and Operation
Maintenance and Troubleshooting
Warranty
Installation Manual
7035000K
Heavy Duty Submersible Effluent/Dewatering Pumps
Models
250-Series 1/3 HP
280-Series 1/2 HP
290-Series 3/4 HP
FL30-Series 1/3 HP
FL50-Series 1/2 HP
FL60-Series 6/10 HP
FL70-Series 3/4 HP
FL100-Series 1 HP
FL150-Series 1-1/2 HP
FL200-Series 2 HP

Questions and Answers

  • S
    Sarah CollinsAug 8, 2025
    Why Liberty Pumps 257 Water Pump won't run?
    • A
      aaronallenAug 8, 2025
      If your Liberty Pumps Water Pump isn't running, there are several potential causes. It could be due to a blown fuse or power interruption, or improper voltage. Ensure the unit is securely plugged in and have an electrician inspect the wiring. The switch may be obstructed, preventing it from turning on, so ensure the pump or switch has enough clearance. Also, the liquid level might be insufficient to activate the switch. Finally, the switch itself could be defective and need replacement.
  • W
    William PatelAug 15, 2025
    What to do if Liberty Pumps 257 runs but doesn't pump?
    • M
      melissataylorAug 15, 2025
      If your Liberty Pumps Water Pump runs or hums but isn't pumping water, consider these possibilities. The discharge line might be blocked; check for any obstructions, including ice if the line runs through cold areas. The check valve could be stuck or installed backward; remove and inspect it. Ensure that any gate or ball valves are open. The pump's total lift capability might be exceeded; try routing the piping to a lower level, or consult the factory about a larger pump. Lastly, the impeller could be jammed or the volute casing plugged; remove the pump, detach the base, clean around the impeller, and reinstall.
  • K
    Kathy KelleyAug 21, 2025
    What to do if Liberty Pumps Water Pump will not turn off?
    • J
      Jennifer SimmonsAug 21, 2025
      If your Liberty Pumps Water Pump won't turn off, it could be caused by a couple of things. The switch might be obstructed, preventing it from moving to the 'turn off' position. Ensure the pump or switch has adequate clearance for free operation. Alternatively, the switch itself could be defective and require replacement.
  • A
    Aaron RobinsonAug 27, 2025
    How to fix a noisy Liberty Pumps 257?
    • J
      Jessica HuffAug 27, 2025
      A noisy Liberty Pumps Water Pump could be due to several reasons. There might be foreign objects in the impeller cavity; remove the pump, detach the base, clean the impeller area, and reassemble. A broken impeller could also be the culprit, consult the factory for information regarding replacement of impeller. Worn bearings can cause noise; return the pump to the factory or authorized repair station for repair. Finally, rigid piping attachments to the building can transmit noise; replace part of the discharge line with a rubber hose or connector.
  • H
    Heidi AndersonSep 1, 2025
    Why does Liberty Pumps 257 Water Pump run periodically?
    • M
      Michael GrahamSep 1, 2025
      If your Liberty Pumps Water Pump runs periodically even when fixtures aren't in use, it could be due to a check valve issue. The check valve might be missing, stuck open, or leaking; remove and inspect it for proper function and installation. Another possibility is leaking fixtures; repair any leaks to stop the pump from cycling unnecessarily.

Summary

General Information

Tools Required

Lists the necessary tools for pump installation and maintenance, ensuring proper execution of tasks.

Removal of old pump

Provides step-by-step instructions for safely disconnecting and removing an existing pump from the basin.

Model Specifications

Dewatering; Sump Applications

Effluent Applications

Simplex (One Pump) Systems

Specific installation guidance for single-pump (simplex) systems, including float switch setup and discharge connections.

Duplex (Two Pump) Systems

Installation instructions for dual-pump (duplex) systems, detailing float arrangement and discharge management.

Electrical Service and Operation

Maintenance

Troubleshooting

3 Year Limited Warranty