PROGRAMMING INSTRUCTIONS
WITH POWER ON, HOAs OFF, FLOATS OFF OR DISCONNECTED, PRESS DESIRED FLOAT BUTTON RAPIDLY 4 TIMES AND HOLD
**PUMP LEDs WILL FLASH UPON SUCCESSFUL PROGRAMMING**
OPTIONS FLOAT BUTTON DEFAULT OPERATION
PUMP FAIL ALARM STOP ON ACTIVATES IF A PUMP CAUSES “LAG” 3 CYCLES IN A ROW
MANUAL ALARM RESET LEAD OFF LATCHES HIGH ALARM: CLEAR WITH EXTERNAL TEST SWITCH
SEAL FAIL HORN LAG OFF ACTIVATES HORN UPON SEAL FAIL
ALARM FLASHER ALARM OFF FLASHES BEACON UPON HIGH ALARM
ALARM CONDITIONS
ALARM BEACON CONTROLLER LED HORN
PUMP FAIL FLASHING RED PUMP LIGHT NO
SEAL FAIL FLASHING SF1, SF2 PROG
FLOAT FAIL FLASHING BAD FLOAT NOT LIT NO
HIGH ALARM SOLID ALARM FLOAT YES
STOP LEAD LAG ALARM
PUMP
1
PUMP
2
HAND
AUTO
HAND
AUTO
NO C NC
OFF
1-2 ALT 2-1
SF1
SF2
25K
5K
NC
150K
100K
125K50K
15K
OFF ON
TEST TEST TEST TEST
SEAL FAIL
POWER
3
4
1
2
5
6
7
8
9
10
AUX
1-2 ALT 2-1
SF1
SF2
SEAL FAIL
LEAD / LAG
SELECTOR
25K
5K
NC
150K
100K
125K50K
15K
SF1
100K
LAG ALARM
TEST TEST TESTTEST TEST
AUX
CONTACTS
NO C NC
6 7 8 9 10
TB2
H
O
A
TM
H
O
A
PUMP 1 PUMP 2
H
O
A
PUMP 1 PUMP 2
H
O
A
H
O
A
TM
H
O
A
1-2 ALT 2-1
LEAD / LAG
SELECTOR
PUMP 1PUMP 1
STOP
TESTTEST
H
O
A
L1 N
ON OFF
1 2
TM
H
O
A
43
1054970
DUPLEX
CONTROLLER
PUMP 1PUMP 1
STOP
TESTTEST
H
O
A
L1 N
ON OFF
1 2
TM
H
O
A
4
3
1054970
DUPLEX
CONTROLLER
PUMP 1 PUMP 2PUMP 1 PUMP 2
STOP LEAD LAG ALARM
TEST TEST TEST TESTTEST TEST TEST
AUX
CONTACTS
NO C NC
4 5 6 7 8 9 10
3
TB1
ON OFF
L1 N
ON OFF
1 2
1054970
DUPLEX
CONTROLLER
TB1
AUX
CONTACTS
NO C NC
10
STOP LEAD LAG ALARM
PUMP
1
PUMP
2
HAND
AUTO
HAND
AUTO
NO C NC
OFF
1-2 ALT 2-1
SF1
SF2
25K
5K
NC
150K
100K
125K50K
15K
OFF ON
TEST TEST TEST TEST
SEAL FAIL
POWER
3
4
1
2
5
6
7
8
9
10
AUX
SF1
100K
LAG ALARM
TEST TEST TESTTEST TEST
AUX
CONTACTS
NO C NC
6 7 8 9 10
TB2
PUMP 1 PUMP 2PUMP 1 PUMP 2
STOP LEAD LAG ALARM
TEST TEST TEST TESTTEST TEST TEST
AUX
CONTACTS
NO C NC
4 5 6 7 8 9 10
3
TB1
L1 N
3
TB1
PUMP 1PUMP 1
STOP
TESTTEST
H
O
A
L1 N
ON OFF
1 2
TM
H
O
A
43
1054970
DUPLEX
CONTROLLER
PUMP 1PUMP 1
H
O
A
H
O
A
OFF ON
POWER
1
2
22650 County Highway 6
Detroit Lakes, MN 56501 USA
Tel: 218-847-1317
Email: sje@sjerhombus.com
Web: www.sjerhombus.com
PUMP 1 PUMP 2
H
O
A
PUMP 1 PUMP 2
H
O
A
STOP LEAD LAG ALARM
TEST TEST TEST TESTTEST TEST TEST
AUX
CONTACTS
H
O
A
L1 N
ON OFF
1 2
H
O
A
NO C NC
4 5 6 7 8 9 103
1-2 ALT 2-1
SF1
SF2
SEAL FAIL
LEAD / LAG
SELECTOR
25K
5K
NC
150K
100K
125K50K
15K
1058484A
TB1 TB2
DUPLEX
CONTROLLER
1055156
a
b
c
e
d
g
l
k
i
j
h
COMPONENTS
a. ON/OFF Switch - Control/Alarm Power g. Simulate Float Buttons x4
b. 120V Incoming Power Terminals h. Float Terminals x8
c. Power LED - (Green) i. Lead/Lag Selecter Switch
d. Pump HOA Switches j. Dual Seal Fail Pot - (Optional)
e. Float LEDs - (Red) x4 k. Dual Seal Fail LEDs - (Red) - (Optional)
f. Pump LEDs
Pump Run - (Green)
Pump Fail - (Red)
l. Auxiliary Alarm Terminals
Model shown contains optional Seal Fail circuitry.
Three Phase Duplex
This control panel must be installed and serviced by a licensed electrician in
accordance with the National Electric Code NFPA-70, state and local electrical codes.
UL Type 4X enclosures are for indoor or outdoor use.
Warranty void if panel is modied.
A Family and Employee Owned Company
Liberty Pumps oers a three-year limited warranty.
For complete terms and conditions, please visit www.libertypumps.com.
Products returned must be cleaned, sanitized, or decontaminated as necessary
prior to shipment to ensure that employees will not be exposed to health
hazards in handling said material. All applicable laws and regulations shall apply.
?
Three Phase
Duplex
Installation
and Operation Manual
This control panel must be installed
and serviced by a licensed electrician
in accordance with the National Electric
Code NFPA-70, state and local electrical
codes.
UL Type 4X enclosures are for indoor or
outdoor use.
Technical support,
service questions:
1-800-543-2550
Monday - Friday
7:00 AM to 6:00 PM EST
?
Manufactured by SJE Rhombus®
AE4=3-131, AE34=3-141, AE34=3-171,
AE34=3-191, AE34=3-511, AE34=4-131,
AE34=4-141, AE34=4-171, AE34=4-191,
AE34=4-511, AE54=3-121, and AE54=4-121
Parts Included
x3
or
x4
Control panel may be
ordered with or
without these items.
x4
AE34=3-131, AE34=3-141, AE34=3-171,
AE34=3-191, AE34=3-511, AE34=4-131,
AE34=4-141, AE34=4-171, AE34=4-191,
AE34=4-511, AE54=3-121, and AE54=4-121
Installation and Operation Manual
Manufactured by SJE Rhombus
®
Call factory with servicing questions:
1-800-543-2550
f
© 2019 SJE, Inc. All Rights Reserved.
SJE RHOMBUS is a trademark of SJE, INC.
PN 1038909E • Rev 08/19
Copyright © Liberty Pumps, Inc. 2019 All rights reserved. Specications subject to change without notice. 7228000E P4
7000 Apple Tree Avenue Bergen, NY 14416
Phone 800-543-2550
Fax 585-494-1839
Email Liberty@LibertyPumps.com
Web www.LibertyPumps.com
Copyright © Liberty Pumps, Inc. 2019 All rights reserved. Specications subject to change without notice. 7228000E P1
7000 Apple Tree Avenue Bergen, NY 14416
Phone 800-543-2550
Fax 585-494-1839
Email Liberty@LibertyPumps.com
Web www.LibertyPumps.com
Cable Weight available
separately. Order Liberty
Pumps Kit #001388

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Liberty Pumps AE Series and is the answer not in the manual?

Liberty Pumps AE Series Specifications

General IconGeneral
BrandLiberty Pumps
ModelAE Series
CategoryWater Pump
LanguageEnglish

Related product manuals