LIFEtech™MOD1C
Owner’s Manual
AM-HLTMC-OM
Rev AA January 2018
20
Charge
Profile
For selecting the right charging profile for the application:
Ionic, Evolution, ENVIROLINK™, Opportunity, Cold Storage, XFCBLC
Auto Start
On- Charge will automatically start when battery is plugged in.
Off- User must push Stop/Start button for charge to start.
Charge Delay
Type - sets OFF, DELAY, or TIME OF DAY.
Value hour delay - sets the amount or time of day for the delay (00:00 to 24:00).
Delay: Start of charge is delayed for the amount of time stored in VALUE (0 to 24 hours)
Time of Day: Charge will not start until the time of day stored in VALUE (24 hour format).
Daily Charge
On/Off Sets daily charge on or off.
Daily Chg Start Sets daily charge start time.
Daily Chg End Sets daily charge end time.
Block Out Charge
On/Off Sets block out charge on or off.
Block out Start Sets daily charge start time.
Block Out End Sets daily charge end time.
Floating
On/Off- Sets float mode on or off.
Current Sets float current.
Voltage Sets float voltage.
This feature can be turned ON or OFF depending on the application. A float charge at
the end of standard charge is intended to compensate for consumption by the truck
electronics that are left on when truck is not used (typically AGV). The parameter
VOLTAGE is in mVpc (millivolts per cell) determines the maximum float voltage. The
parameter CURRENT defines the current output during float, the current will
automatically decrease to keep the battery voltage at the maximum defined by the
VOLTAGE parameter.