AM-HLTMC-OM
Rev AA January 2018
Fault Codes
Fault Display
In case of a fault, one of the corresponding fault codes listed below will appear on the display.
If it is a critical fault, charging will stop and the red Fault LED will be illuminated.
DF1
Yes Low output current
Check input voltage and fuses. Call
for service.
DF2
Yes Output fault
Check for proper battery connection
(reversed polarity). Check output fuse.
DF3
Yes Improper battery
Battery voltage too high (>2.3 Vpc) or
too low (<1.6 Vpc). Use proper
DF4
No
discharged more than 80%
Prevent future over discharging of
battery. Battery charge gauges and lift
interrupts may need calibration.
DF5
No Battery requires inspection
Non critical fault. Check battery cables
for condition and size, check for loose
connections, check for defective cells.
TH
Yes Charger overheating
Check that fans are working. Verify
that ambient temperature is not too
high. Inspect to see if charger
ventilation is obstructed or impaired.
No Low battery electrolyte Check battery electrolyte level.