5. Set the rotary switch to 200 k.
6. Connect the red test lead to the secondary outlet and the black
test leads to the primary - pole as fig 5.
The secondary outlet is generally in range 6 k to 30 k. Refer to
various kind of automotives manuals.
Battery condition test
Test if battery is fully charged.
1. Set the rotary switch to 20 VDC position.
2. Insert the red test lead into the V terminal and the black test lead
into the COM terminal.
3. Turn off the ignition switch.
4. Turn on the driving lights for 10 sec. to release charges from the
battery.
5. Connect the black test lead to the battery negative pole and the
red to the positive pole.
The testing result are shown in contrast as follows. 12,6V-100%.
12,45V-75%. 12,3V-50%. 12,15V-25%.
Battery consumption test when the engine is off
The test is useful for determination of the additional consumption of
the battery.
1. Turn off ignition key and make sure lights etc are closed.
2. Set the rotary switch to 10A position.
3. Insert the red test lead into the A terminal and the black test lead
into the COM terminal.
4. Cut off the cable to the battery positive pole and connect the red
test lead to the battery positive pole and the black test lead to the
cable. The measured value shows on the display.
Power consumption to a frequent-modulated radio or clock needs a
current supply of 100 mA. If there emerges any additional current do
necessary service.
500
Auto
manual_limit500auto.qxd 05-06-08 16.25 Sida 15