Questions and Answers

  • B
    Bobby HughesAug 17, 2025
    What to do if there is no motor sound or movement of piston rod in Linak Controller?
    • A
      Amanda AvilaAug 17, 2025
      If there's no motor sound or piston rod movement in your Linak Controller, first ensure the actuator is properly connected to the control box. A blown fuse in the control box could also be the cause, requiring a fuse replacement. Finally, a damaged cable could be the reason; in this case, the actuator should be sent for repair.
  • B
    Brandy EatonAug 20, 2025
    Why power indicator does not light up on Linak Controller?
    • R
      robertsdarrylAug 20, 2025
      If the power indicator on your Linak Controller doesn't light up, start by ensuring it's connected to the mains. If it is, check the fuse; replace it if the system allows external fuse replacement. A defective power cable could also be the issue; if the cable is exchangeable, try a new one. If not, or if the control box is defective, the unit needs repair.
  • S
    Sarah HendersonAug 22, 2025
    How to fix motor that runs too slowly on Linak Controller?
    • C
      Catherine MayAug 22, 2025
      If the motor on your Linak Controller runs too slowly or lacks full force, the issue might be an insufficient power supply; try increasing it. Alternatively, a voltage drop in the cable could be the cause, necessitating a thicker cable.
  • N
    nharmonAug 26, 2025
    Why Linak Controller control box is completely dead on battery?
    • M
      Michael AndrewsAug 26, 2025
      If the control box of your Linak Controller is completely dead on battery and there's no relay clicking, the battery might be completely flat; try charging it. If charging doesn't help, the battery may be defective and needs replacement.
  • A
    Adam RossAug 28, 2025
    What to do if actuator does not run on battery, but relay clicking can be heard on Linak Controller?
    • M
      Matthew LyonsAug 28, 2025
      If the actuator doesn't run on battery, but relay clicking can be heard on your Linak Controller, ensure the actuator plug is properly pushed into the control box. If that's not the issue, the actuator might be defective and needs replacement.
  • K
    Kyle CurtisAug 30, 2025
    Why are the control box relays clicking on Linak Controller?
    • C
      Charles FuentesAug 30, 2025
      If the control box relays are clicking on your Linak Controller, the actuator may be defective, requiring replacement. Alternatively, the control box itself could be defective and needs to be replaced.
  • U
    ustewartSep 2, 2025
    How to fix motor run with quick release malfunction on Linak Controller?
    • D
      Denise DaySep 3, 2025
      If the motor runs but the quick release doesn't function or is noisy on your Linak Controller, it could be because the declutching arm turns less than approximately 75 °C. In this case, adjust the cable.
  • J
    Julie Le MDSep 5, 2025
    What to do if piston rod will only move inwards on Linak Controller?
    • R
      Rachel RosalesSep 5, 2025
      If the piston rod will only move inwards and not outwards on your Linak Controller, it's possible the safety nut has operated. In this situation, send the actuator for repair.
  • L
    Luis AdamsSep 8, 2025
    Why actuator cannot lift full load on Linak Controller?
    • D
      Daniel HendricksSep 8, 2025
      If the actuator cannot lift a full load on your Linak Controller, it may be due to a worn clutch or a damaged motor. In either case, send the actuator for repair.
  • T
    timothy52Sep 12, 2025
    What to do if motor runs but spindle does not move on Linak Controller?
    • J
      Jacqueline ScottSep 12, 2025
      If the motor runs but the spindle does not move on your Linak Controller, it is likely that the gear wheel or spindle is damaged, requiring the actuator to be sent for repair.

Summary

System Description

Mounting

Provides instructions and torque specifications for mounting actuators, control boxes, and accessories.

Information on Start-up, De-installation and Operation

Troubleshooting Actuators;Lifting Columns

Lists symptoms, possible causes, and actions for actuator and lifting column issues.

Troubleshooting Electronics

Lists symptoms, possible causes, and actions for electronic component issues.

Information on Specific Actuators

LA20 Inline

Details features, usage, warnings, and recommendations for the LA20 Inline actuator.

LA23 DESKLINE

Describes the LA23 DESKLINE actuator, its features, usage, warnings, and recommendations.

LA23 MEDLINE CARELINE TECHLINE

Covers the LA23 MEDLINE/CARELINE/TECHLINE actuator, including specifications and warnings.

LA40

Information on the LA40 HOMELINE actuator, including usage, recommendations, and warnings.

LA43

Details the LA43 MEDLINE/CARELINE actuator, covering usage, recommendations, and warnings.

Information on Specific Columns

BB3

Information about the BB3 3-part telescopic actuator for vertical bed lifts.

Information on Specific Control Boxes

Information on Specific Controls

Information on Specific JUMBO

CBJ1; CBJ2

Information on CBJ1/CBJ2 control boxes for JUMBO system, developed for patient lifts.

CBJ-Care

Describes the CBJ-Care control box, part of the JUMBO system for patient lifts.

CBJ-Home

Details the CBJ-Home solution for patient lifts, with integrated control box and battery.

Linak LA20 Specifications