    What to do if there is no motor sound or movement of piston rod in Linak Controller?
    • E
      Elijah FrederickAug 17, 2025
      If there's no motor sound or piston rod movement in your Linak Controller, first ensure the actuator is properly connected to the control box. A blown fuse in the control box could also be the cause, requiring a fuse replacement. Finally, a damaged cable could be the reason; in this case, the actuator should be sent for repair.
  • C
    Christopher TurnerAug 19, 2025
    Why power indicator does not light up on Linak Controller?
    • B
      Brenda KelleyAug 19, 2025
      If the power indicator on your Linak Controller doesn't light up, start by ensuring it's connected to the mains. If it is, check the fuse; replace it if the system allows external fuse replacement. A defective power cable could also be the issue; if the cable is exchangeable, try a new one. If not, or if the control box is defective, the unit needs repair.
  • J
    Joseph MartinezAug 22, 2025
    How to fix motor that runs too slowly on Linak Controller?
    • E
      Elizabeth HawkinsAug 22, 2025
      If the motor on your Linak Controller runs too slowly or lacks full force, the issue might be an insufficient power supply; try increasing it. Alternatively, a voltage drop in the cable could be the cause, necessitating a thicker cable.
  • D
    Dennis HallAug 25, 2025
    Why Linak Controller control box is completely dead on battery?
    • J
      Jennifer AndersonAug 25, 2025
      If the control box of your Linak Controller is completely dead on battery and there's no relay clicking, the battery might be completely flat; try charging it. If charging doesn't help, the battery may be defective and needs replacement.
  • R
    Ronald GrantAug 27, 2025
    What to do if actuator does not run on battery, but relay clicking can be heard on Linak Controller?
    • K
      Kimberly KaneAug 27, 2025
      If the actuator doesn't run on battery, but relay clicking can be heard on your Linak Controller, ensure the actuator plug is properly pushed into the control box. If that's not the issue, the actuator might be defective and needs replacement.
  • L
    Lauren LongAug 30, 2025
    Why are the control box relays clicking on Linak Controller?
    • N
      Natasha CollinsAug 30, 2025
      If the control box relays are clicking on your Linak Controller, the actuator may be defective, requiring replacement. Alternatively, the control box itself could be defective and needs to be replaced.
  • D
    Dale TuckerSep 1, 2025
    How to fix motor run with quick release malfunction on Linak Controller?
    • N
      Nicole BoltonSep 2, 2025
      If the motor runs but the quick release doesn't function or is noisy on your Linak Controller, it could be because the declutching arm turns less than approximately 75 °C. In this case, adjust the cable.
  • B
    benjamin73Sep 4, 2025
    What to do if piston rod will only move inwards on Linak Controller?
    • M
      Mary RhodesSep 4, 2025
      If the piston rod will only move inwards and not outwards on your Linak Controller, it's possible the safety nut has operated. In this situation, send the actuator for repair.
  • C
    Christopher HarperSep 7, 2025
    Why actuator cannot lift full load on Linak Controller?
    • M
      michelle47Sep 7, 2025
      If the actuator cannot lift a full load on your Linak Controller, it may be due to a worn clutch or a damaged motor. In either case, send the actuator for repair.
  • X
    xjenkinsSep 10, 2025
    What to do if motor runs but spindle does not move on Linak Controller?
    • E
      Erica StevensonSep 10, 2025
      If the motor runs but the spindle does not move on your Linak Controller, it is likely that the gear wheel or spindle is damaged, requiring the actuator to be sent for repair.

Summary

Important Information

Safety Warnings and Recommendations

Key safety instructions, warnings, and recommendations for product usage, including handling and system operation.

General Assembly Instructions

General Warranty Periods

Connecting the System

Battery Information

Troubleshooting Guides

Information on Specific Actuators

LA20 Inline (MEDLINE CARELINE)

Detailed information, warnings, usage, and recommendations for the LA20 Inline actuator.

LA23 (DESKLINE)

Information, warnings, and recommendations for the LA23 DESKLINE actuator, including cable lock instructions.

LA30 (MEDLINE CARELINE TECHLINE)

Information on the LA30 actuator, including usage, recommendations, improved self-locking, and noise levels.

LA40 (MEDLINE CARELINE )

Details on the LA40 MEDLINE/CARELINE actuator, including recommendations, warnings, and usage specifications.

LA43 (MEDLINE CARELINE )

Information on the LA43 actuator, including recommendations, warnings, self-locking ability, and safety concept.

LA44 (MEDLINE CARELINE )

Details on the LA44 actuator, including self-locking ability, usage, recommendations, and safety features.

Information on Specific Columns

BL1 (MEDLINE CARELINE TECHLINE)

Details on the BL1 lifting column, including usage, compatibility, mounting guidelines, and warnings.

BL4 (MEDLINE CARELINE)

Information on the BL4 lifting column, including usage, technical specifications, warnings, and mounting guidelines.

LC3 (MEDLINE CARELINE)

Details on the LC3 lifting column, including usage, mounting instructions, recommendations, and warnings.

LP2 (DESKLINE MEDLINE CARELINE TECHLINE)

Information on the LP2 vertical lifting column, including usage, warnings, and mounting considerations.

Information on Specific Control Boxes

CA30;CA40 (MEDLINE CARELINE)

Details on CA30/CA40 control boxes, including usage, LED indicator, mounting instructions, and cable management.

Information on Specific Controls

Information on Specific JUMBOTM

Information on Specific Accessories

Care Communication System (CCS)

Repair and Disposal

Linak LA28 Compact Specifications

General IconGeneral
BrandLinak
ModelLA28 Compact
CategoryController
LanguageEnglish

Related product manuals