Installation Preparation
Work Surfaces and Areas
Ensure that the work surface upon which the appliance is to be sited is capable of sustaining
the working weight of the appliance.
Consideration should be given for servicing requirements.
Ensure that safe operational access to the appliance is unrestricted.
Do not site the appliance directly beneath wall cupboards, other wall mounted appliances and
low ceilings that are susceptible to damage from water vapour.
Where the appliance is to be wall mounted it is recommended that the safe working height
from the floor to the faucet is approximately 1400mm.
Water Connection
Connection to the cold water supply and the appliance is made via the hose supplied. The
hose can be found inside the tank of the appliance and must be removed before installation
and commissioning.
In hard water areas it is advisable to fit a filtration unit to limit scale deposits. A filter kit is
available as an optional extra.
Electrical Connection
All electrical work must comply with all relevant wiring regulations and carried out by a
qualified electrician.
EB3 models require a 13Amp-supply socket.
EB4 models require a 20Amp supply.
EB6 models require a 30Amp single or multi-phase supply.
Isolation switches for the appliance must not be obstructed and be within easy reach.
Overflow and Drainage
Due to the electronic function of the water boiler it is highly unlikely than an overflow would
occur. The boiler is primarily designed so that any overflow occurrence and condensation is
directly vented to the spillage tray.
As an option the boiler overflow outlet may be connected to a drainage system.
Note: There may some steam emissions from the vent at the base of the appliance during the
initial fill stages but the steam emissions will lessen as the volume of water increases in the tank.
As an alternative the internal flexible hose may be redirected. See notes on Overflow and
Drainage in the Installation section.
WARNING. The flexible hose connected from the over flow also acts as a vent for the appliance.
Under no circumstances should this flexible hose become blocked or restricted in any way.