EasyManua.ls Logo

Lincoln Electric Flextec 350XP - User Manual

Lincoln Electric Flextec 350XP
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Operator’s Manual
Flextec
Construction
®
350XP & Flextec 350X
Register your machine:
www.lincolnelectric.com/register
Authorized Service and Distributor Locator:
www.lincolnelectric.com/locator
IM10570 | Issue D ate Jul- 21
© Lincoln Global, Inc. All Rights Reserved.
For use with machines having Code Numbers:
Flextec® 350XP:13067, 13069,
13071
Save for future reference
Date Purchased
Code: (ex: 10859)
Serial: (ex: U1060512345)
Need Help? Call 1.888.935.3877
to talk to a Service Representative
Hours of Operation:
8:00 AM to 6:00 PM (ET) Mon. thru Fri.
After hours?
Use “Ask the Experts” at lincolnelectric.com
A Lincoln Service Representative will contact you
no later than the following business day.
For Service outside the USA:
Email: globalservice@lincolnelectric.com
Flextec® 350X Construction:
13066, 13068, 13070, 13073
®
Flextec 350XP
Flextec 350X Construction

Questions and Answers

  • C
    Cynthia MejiaAug 13, 2025
    What to do if my Lincoln Electric Flextec 350XP Welding System won't weld or has no output?
    • S
      Shelly HudsonAug 13, 2025
      If the displays show an error code, consult the fault section for the appropriate corrective steps. If the thermal symbol illuminates, refer to the thermal section. If the output terminals are in remote control mode, switch to 'ON' and check for output voltage. If output voltage is present, verify the remote control connection and its operation.
  • W
    Whitney RomeroAug 16, 2025
    Why is the thermal symbol lit on my Lincoln Electric Flextec 350XP?
    • J
      joshua51Aug 16, 2025
      If the thermal symbol is lit, check that the fan is working correctly. Ensure that there are no obstructions blocking the intake or exhaust louvers. Use air to blow out any dirt from the fan through the rear louvers. Note that the fan may automatically shut off 5 minutes after welding stops. If welding output ratings have been exceeded, allow the machine to cool down and reset.
  • H
    hadamsAug 21, 2025
    What to do if the output voltage limit is exceeded on my Lincoln Electric Welding System?
    • M
      Micheal JohnstonAug 21, 2025
      If VRD is enabled, and the stud voltage exceeds 35 volts peak, or in standard operation, the stud voltage exceeds 113 volts peak, verify the voltage feedback leads are correctly connected inside the machine. Also, ensure the input voltage is within +/- 10% of the nominal value.
  • E
    egarciaAug 25, 2025
    Why does my Lincoln Electric Flextec 350XP show a thermal fault?
    • A
      Albert PetersonAug 25, 2025
      If the machine shut off output due to high internal temperatures, check for any obstructions blocking the intake or exhaust louvers. Blow air into the rear louvers to remove any dirt from the fan. Note that the fan is designed to automatically turn off 5 minutes after welding has stopped. If welding output ratings have been exceeded, allow the machine to cool down and reset. You can also measure the thermostats at the switchboard and replace them if they are defective.
  • K
    Kaitlyn MaldonadoAug 28, 2025
    What causes a communication fault in my Lincoln Electric Welding System?
    • A
      andersonmargaretAug 28, 2025
      Power cycle the machine to reset the error. Inspect the CAN harness to ensure that all connections are secure and in good condition. Check the power supply to the User Interface and Switch PC boards. Replace any defective components as needed.
  • J
    Jessica Coleman DDSSep 1, 2025
    How to troubleshoot a Lincoln Electric Welding System wire feeder that isn't working?
    • W
      Wesley DiazSep 1, 2025
      Check the control cable connectors on the front of the machine to ensure they are properly connected. Check the circuit breaker on the back of the machine and reset it if necessary. Also, check the control cable between the power source and the wire feeder for continuity.
  • D
    David HorneSep 4, 2025
    What causes a primary overcurrent error in my Lincoln Electric Welding System?
    • L
      Lauren CombsSep 4, 2025
      Check the input power (voltage and frequency). Verify proper input power and welding output cable connections. Verify proper connections of main internal power components. The machine must be power cycled to reset the error.
  • S
    sergio14Sep 8, 2025
    What to do if the device that controls the sequence of the welding operation halted due to an error on my Lincoln Electric Welding System?
    • E
      erobertsSep 8, 2025
      For weld terminals in remote mode, re-trigger to recover from the error. For weld terminals in local mode, toggle the Remote/Local switch to recover from the error.

Lincoln Electric Flextec 350XP Specifications

General IconGeneral
Duty Cycle60% at 350A
Rated Output350A/34V/100%
ProcessesMIG, Stick, TIG
Wire Feed Speed Range50-700 IPM