FORM 403084
JANUARY 2003
2
RF Meter
TABLE OF CONTENTS
Definitions..........................................................................................1
Keypad Buttons.................................................................................2
Meter Installation................................................................................3
Operating the Meter........................................................................4-5
Changing Factory Settings.............................................................6-7
Dimensional Drawing.........................................................................8
Specifications....................................................................................8
Parts Drawing...............................................................................9-12
Factory Settings
Each meter is preprogrammed and calibrated at the factory. Unless
otherwise specified at the time of the order, each meter is pro-
grammed in quarts for use with motor oil. The meter is shipped in the
Manual Mode. If you need to change the factory settings, see page 6.
1000 psi (67 bar) Maximum Working Pressure
8 gpm (30 Lpm) Maximum Flow Rate
IMPORTANT I!!! This manual contains important warnings
and in formation. READ AND KEEP FOR REFERENCE.
SYMBOLS
Equipment Misuse Hazard
1. This equipment is for professional use only.
2. Read all instructions, tags, and labels before operating the
equipment.
3. Use the equipment only for its intended purpose.
4. Do NOT modify or alter the equipment.
5. Do NOT leave equipment unattended while dispensing.
6. Check equipment daily. Repair or replace worn or damaged
parts immediately.
7. Do NOT exceed the maximum working pressure level of the
lowest rated system component.
8. Use only extensions and nozzles that are designed for use
with this equipment.
9. Use only fluids and solvents that are compatible with the
equipment. Read all fluid and solvent manufacturerās
warnings.
10.Tighten all fluid connections before operating this equipment.
11. Do NOT stop or deflect leaks with hands, body, gloves, or
rags.
12. Do NOT dispense valves towards any person or any part of
the body.
13. Do NOT place hands or fingers over the end of or into the
dispense valve.
14. Comply with all local, state, and federal fire, electrical, and
safety regulations
15. Use of this product in a manner other than specified in this
manual may result in impaired operation or damage to
equipment.
Keypad Buttons
Used to enter the quantity to be dispensed when RF
communications are not available.
Total
Used to display the accumulated total of fluid, as well as
the resettable total during normal operating mode.
Auto
Used to enter and exit the Auto Mode when RF
communications are not available.
Reset
Used to accept a dispense order from the keypad. Used
in normal operating mode (RF, manual or auto) to clear
the previously programmed batch and to reset the meter.
Used to reset the resettable total after pressing the
TOTAL button.
Shut-Off
Used to stop the flow through an electrical override.
Meter Display and Keypad
This symbol is an alert to the possibility of serious injury or
death if the instructions are not followed.
This symbol is an alert to the possibility of damage to or
destruction of equipment if the instructions are not followed.