PROGRAMMING INSTRUCTIONS
· PROGRAMMING SWITCH
Located on underside of module. Must be depressed 5
seconds and released to activate the programming proce-
dure.
· TOTAL BUTTON
a.) When depressed alone, it will display total GALLONS or
LITERS used from inventory.
b.) When depressed in the programming mode, it will allow
you to select any item to be changed.
· RESET BUTTON
a.) When depressed momentarily, it will clear the display.
b.) When depressed in the programming mode, it will
change any flashing object on the display.
· TO CHANGE UNITS OF MEASURE
a.) Remove 3 screws holding electronic register module to
lube meter body.
b.) Depress the PROGRAMMING switch on bottom of
module for 5 seconds and release to activate the
programming
procedure. A unit of measure symbol will flash.
c.) Toggle RESET button until desired unit of measure
symbol appears.
d.) Again depress the PROGRAMMING switch on bottom of
module for 5 seconds and release to end the
programming procedure. This operation will lock in the
selected program and blank the display.
NOTE: Changing any unit of measure will reset the
totalizer to zero.
· TO RECALIBRATE
Example: Meter delivers 4.200 quarts.
Display shows only 4.000 quarts dispensed.
4.2(qty. delivered) divided by
4.0(qty. displayed) = 1.05 (error factor)
a.) Display existing meter correction factor by depressing
and holding TOTAL and RESET buttons.
Example: 0.995. (Make a note of this number.)
b.) Calculate a new meter correction factor: 0.995 (existing
meter correction factor) X 1.05 (calculated error factor) =
1.045 (new meter correction factor).
c.) Remove 3 screws holding register module to meter.
d.) Depress the PROGRAMMING switch on bottom of
module for 5 seconds and release to activate the
programming procedure.
e.) Display will show existing meter correction factor and
programmed unit of measure symbol will be flashing.
f.) Toggle TOTAL button until left most correction factor digit
that you wish to change begins to flash.
g.) Toggle RESET button until desired digit (1) appears.
h.) Toggle TOTAL button until the next digit you wish to
change begins to flash.
i.) Toggle RESET button until the desired digit (0) appears.
j.) Toggle TOTAL button until the next digit you wish to
change begins to flash.
k.) Toggle RESET button until the desired digit (4) appears.
I.) Toggle TOTAL button until the next digit you wish to
change begins to flash.
m.)Toggle RESET button until the desired digit (5)
appears.
n.) Again depress the PROGRAMMING switch for 5 sec-
onds and release to end the programming procedure.
This operation will lock in the selected program and
blank the display. Reinstall the register to the lube
meter.
NOTE: After programming, display will be blank. Depress
RESET or TOTAL button to reactivate the display.
NOTE: Original meter correction factor is written on top of
meter housing in black ink when factory calibrated. It
may have been revised after field installation. Use
correction factor shown on display.
Americas:
One Lincoln Way
St. Louis, MO 63120-1578
USA
Phone +1.314.679.4200
Fax +1.800.424.5359
Europe/Africa:
Heinrich-Hertz-Str 2-8
D-69183 Walldorf
Germany
Phone +49.6227.33.0
Fax +49.6227.33.259
Asia/Pacific:
25 Intl Business Park
#01-65 German Centre
Singapore 609916
Phone +65.562.7960
Fax +65.562.9967
© Copyright 2002
Printed in USA
Web site:
www.lincolnindustrial.com