Section 6
Page 27
Service Training
6.1.14 Horn operation  4H1
The horn circuit is supplied directly from the emergency stop contact. The push button 4S1 is above
the control panel. Pressing 4S1 applies a voltage +24V to the horn 4H1.
HORN
Connector 1X3
Terminal
Colour Function
8 BK(80) +24V Signal