Section 6
Page 45
Service Training
6.4.3 Setting parameters for multifunction indicator / Factory settings
ON TRUCK OPERATION IN FACTORY
The parameters must be customized:
THE DISPLAY (see menus 2 and 5):
- Homepage screen logo (Linde - Lansing)
- The menu language (French, English, German,
Spanish, Italian, Dutch)
- Date format (DDMMYY or MMDDYY)
- Time
- Service Point contact details
PROGRAMMING NEXT MAINTENANCE VISIT
(see menu 2):
- Enabling or disabling the service reminder
- Choosing the enable mode in hours or in days
- Alarm Service X days or Y hours before enabling
DISCHARGE INDICATOR (see menu 4):
- Setting parameters according to the characteristics
of the battery mounted on the truck
The default parameters on leaving the factory are:
-> Truck delivery country logo
-> The delivery country language
-> Enabled
-> at 500 hours
-> 50 hours before
->Truck delivered with a battery:
indicator set according to battery equipment
->Truck delivered without battery:
by default set on the curve Varta 2.09V - 20%
- 0 mn.
6.4.4 Setting the multifunction indicator after a service visit
The technician must activate the next visit reminder (see menu 3) and
through the same operation reset the service alarm.
The technician can open the Bloc Note (see menu 6-6) to store useful information for future interventions.
The technician can also edit the multifunction indicator parameters (see menu 7).