P/N 1604010 Rev D (ECN 35207) 3-1 Multi-Control Operation Manual
Section 3 - Service
Section 3 - Service
System Alerts
All service should be performed by a Lindsay Dealer. For equipment issues or issues with the FieldNET portal /
mobile application, please contact the FieldNET support team at 866.MY.FIELD (866-693-4353) in the USA, or
email support at eldnet@lindsay.com.
Alert Default Level Cause
High System Flow Shutdown 1- High Shutdown due to system ow exceeding the allow-
able limit.
Low System Flow Shutdown 1- High Shutdown due to system ow being lower than the
allowable limit.
High Flow Disparity Shutdown 1- High Shutdown due to ow disparity exceeding the allow-
able variation limit when ow is high.
Low Flow Disparity Shutdown 1- High Shutdown due to ow disparity exceeding the allow-
able variation limit when ow is low.
High System Pressure Shutdown 1- High Shutdown due to system pressure exceeding the
allowable limit.
Low System Pressure Shutdown 1- High Shutdown due to system pressure being lower than
the allowable limit.
High Temperature Shutdown 1- High Shutdown due to system temperature exceeding
the allowable limit.
Low Temperature Shutdown 1- High Shutdown due to system temperature being lower
than the allowable limit.
High Injector Flow Shutdown 1- High Shutdown due to ow through an injector exceeding
the allowable limit.
Low Injector Flow Shutdown 1- High Shutdown due to ow through an injector being
lower than the allowable limit.
High Voltage Shutdown 1- High Shutdown due to system voltage exceeding system
capacity.
Low Voltage Shutdown 1- High Shutdown due to system voltage being too low for
system capacity.
Wireless Switch Battery Shutdown 1- High A wireless switch has caused a shutdown due to a
problem with the battery.
Wireless Switch Solar Panel Error 1- High A wireless switch has caused a shutdown due to a
problem with the solar panel.
Wireless Switch Communication Error 1- High A wireless switch has failed to communicate with
the system after multiple attempts to contact it.
Powered Off While Running Wet 1- High The Multi-Control lost power or turned off while the
system was irrigating.
High Rainfall Shutdown 1- High Shutdown due to rainfall accumulation in the rain
bucket exceeds the programmed limit.
High pH Shutdown 1- High High pH amounts detected in the water exceed the
expected limits.
Low pH Shutdown 1- High pH amounts in the water are lower than the lowest
programmed limit.
Hardware Shutdown 1- High A component failure has caused the shutdown.