Black 0008
Black0008
Select Request-to-Enter Output Default: Relay #1
Sets which output activates when the Request-to-Enter input is
grounded. This output may be timed or toggled.
Press: 1 6
#
Output
#
Output = Output to Activate (0-4)
1 = Relay #1 2 = Relay #2 3 = Output #3
4 = Output #4 0 = No Output
Relay #1 On-time Default: 2 Seconds
Sets the length of time Relay #1 activates when triggered.
Press: 2 1
#
Seconds
#
Seconds = Output time in seconds (0-60)
99 = Toggle mode
Relay #2 On-time Default: 2 Seconds
Sets the length of time Relay #2 activates when triggered.
Press: 2 2
#
Seconds
#
Seconds = Output time in seconds (0-60)
99 = Toggle mode
Solid-state Output #3 On-time Default: 2 Seconds
Sets the length of time Output #3 activates when triggered.
Press: 2 3
#
Seconds
#
Seconds = Output time in seconds (0-60)
99 = Toggle mode
Solid-state Output #4 On-time Default: 2 Seconds
Sets the length of time Output #4 activates when triggered.
Press: 2 4
#
Seconds
#
Seconds = Output time in seconds (0-60)
99 = Toggle mode
Beep Sounds on Keystrokes Default: Yes
Selects whether or not the keypad beeps as each key is pressed.
Press: 4 0
#
Sound
#
Sound = 1 for Yes
= 0 for No
Beep Sounds During Relay #1 Default: No
Selects whether or not the keypad beeps during Relay #1 activation.
Press: 4 1
#
Sound
#
Sound = 1 for Yes
= 0 for No
Beep Sounds During Relay #2 Default: No
Selects whether or not the keypad beeps during Relay #2 activation.
Press: 4 2
#
Sound
#
Sound = 1 for Yes
= 0 for No
Beep Sounds During Output #3 Default: No
Selects whether or not the keypad beeps during Output #3 activation.
Press: 4 3
#
Sound
#
Sound = 1 for Yes
= 0 for No
Beep Sounds During Output #4 Default: No
Selects whether or not the keypad beeps during Output #4 activation.
Press: 4 4
#
Sound
#
Sound = 1 for Yes
= 0 for No
Keypad Lockout Count Default: 3 Tries
Sets the number of incorrect entry code attempts allowed before the
keypad “locks out”.
Press: 5 0
#
Attempts
#
Attempts = Number of attempts before lockout (2-7)
Anti-passback Time Default: No Anti-passback
Sets the length of time an entry code will not function after it is used.
Press: 5 1
#
Minutes
#
Minutes = Time in Minutes (1-4)
0 = No Anti-passback
Master Reset
! CAUTION: Performing a master reset will clear
the entire memory of the AccessKey and return
all programmable options to the factory default
values. ALL ENTRY CODES WILL BE ERASED.
STEP 1 Disconnect power from the keypad.
STEP 2 Press and hold down the
*
and
#
keys.
STEP 3 Apply power to the keypad, continue holding the
keys down until the red LED starts flashing.
STEP 4 Release the keys. The red and yellow LEDs will
remain lit until the process is complete, then the
yellow LED will go out.
Resetting the Master Code
STEP 1 Open the AccessKey case.
STEP 2 Locate jumper JP2. This jumper is used to reset
the master code.
STEP 3 With power applied to the keypad, remove jumper
JP2. The keypad will begin to beep, signaling that
the code has been reset.
STEP 4 Replace jumper JP2.
THE MASTER PROGRAMMING CODE IS NOW 123456.