SMOKE GENERATOR
18
WWW.LIONPROTECTS.COM
6. SERVICE
The Smoke Generator has been designed to require minimal maintenance
and/or service.
ANNUAL MAINTENANCE
Once per year, the Smoke Generator should be ushed with LION Cleaning
Solution, comprised of deionized water. The uid remaining in the tank must rst
be removed and then approximately 3 quarts of Cleaning Solution should be ushed
through the generator. The generator should be run on the Continuous setting until the
uid tank is empty. Any solution left in the tank must be removed.
NOTE
Deionized water is NOT regular water. Using tap, ltered,
or even distilled water will damage your heating core.
LION offers economical maintenance packages to keep your generator running at
optimal levels. Please contact your sales representative for more information.
WATER
The Smoke Generator is water-resistant, not watertight. Some residual moisture
or incidental splashing should not cause damage, but use caution when using the
generator during reghter training sessions. Always ensure that the generator
does not get wet during training operations. Do NOT cover the equipment with a
tarpaulin. This may result in a hazardous situation due to built-up heat from the
generator that cannot dissipate. Smoke ducting kits are available and can be used
to put smoke into areas where hose lines are used.
Pay close attention to the weather when operating the equipment outside
to avoid
unnecessary exposure to water.
The warranty does not cover damage caused by
exposure to water.
MAIN POWER CORD
If the main power cord needs to be replaced, contact LION for assistance.
OPENING AND REPAIRING
The Smoke Generator may only be opened and repaired by qualied staff.