Do you have a question about the LNS Hydrobar Express 332 and is the answer not in the manual?
Bar Length | Unknown |
---|---|
Remnant Retract | Yes |
Profile Capability | Yes |
Control | PLC |
Type | Hydrostatic |
Maximum Bar Diameter | 32 mm |
Loading Capacity | 32 bars |
Magazine Capacity | 32 bars |
Control System | LNS e-Connect |
Power Supply | 400V / 50Hz |
Details alarm for open emergency stop line and its causes/solutions.
Explains alarms due to insufficient oil pressure or faulty pressure switch.
Details alarms for low air pressure or faulty air pressure switch.
Addresses communication issues between servo amplifier and PLC.
Lists and describes servo amplifier faults, their causes, and remedies.
Explains the function and common malfunctions of the front rest.
Discusses causes and solutions for vibration issues during operation.
Step-by-step guide for aligning the front rest to the "H" channel.
Procedure for calibrating the front rest's maximum opening diameter.
Instructions for adjusting the tension of the drive chain.
Restoring PLC program from memory card for v1.17a firmware.
Updating bar feeder parameters from MMI to PLC for v1.17a firmware.
Daily checks including air pressure verification.
Monthly tasks like cleaning the bar feeder and checking hydraulics.
Annual checks including PLC battery and bar feeder alignment.
Lists essential mechanical and electrical spare parts for the bar feeder.
Chart detailing collet part numbers based on guiding channel and bar stock diameter.
Identifies and lists components within the electrical box.