30
Product reservoir not
switched on.
Check product reservoir.
Product reservoir is empty.
Refill product reservoir (see
Section 4.3).
Air bubble in the product
Product reservoir is empty.
Refill product reservoir (see
section 4.3).
Product hose not correctly
connected.
Connect product hose
correctly.
Dispensing valve not
correctly connected or
defective.
Check the dispensing valve
(see instruction manual for
dispensing valve).
Product reservoir pressure is
too high.
Lower pressure and
increase dispensing time.
Pressurized air escapes
between reservoir housing
and reservoir lid.
Reservoir Knob is not
tightened.
Tighten the reservoir knob
O-ring leaks.
Grease or replace the O-
ring.