EasyManua.ls Logo

Loctite PULSE EQ RC50 - Technical Data

Loctite PULSE EQ RC50
41 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8
5. Reservoir Pressure Gauge
6. Reservoir/Feedline Fitting
7. Reservoir Knob x 3
8. Reservoir Lid
9. Socket XS9 PLC Interface
10. Socket XS8 USB
11. ETHERNET
12. 24VDC Power In
13. Low Level Sensor
14. Silencer
15. Air Pressure In
16. Channel B ON Output
17. Channel B OFF Output
18. Channel A ON Output
19. Channel A OFF Output
20. Socket XS1 Channel B
21. Socket XS1 Channel A
3 Technical Data
Dimensions (L x H x W): 214x363x366 mm
Total weight: Kg (lbs.) 12 (26)
Power Supply: 110~240 VAC 50/60Hz
Internal control voltages: 24VDC
Power consumption: Approx. 30 Watts
Pneumatic Supply: Clean, dry air not to exceed 125psi (8.5bar). and
filtered with a maximum of 50 micron.
Operating Temperature: +10 °C to +40 °C (+50 °F to +104 °F)
Storage Temperature: - 10 °C to +60 °C (+14 °F to +140 °F)

Related product manuals