4. Measure the spark plug electrode gap with a suitable gauge.
The gap should be 0.028 in -0.031 in (0.70 mm - 0.80 mm). Correct the gap, if necessary, by
carefully bending the side electrode.
5. Install the spark plug carefully, by hand, to avoid cross-threading.
6. After the spark plug seats, tighten with a spark plug wrench to compress the water.
If reinstalling the used spark plug tighten 1/8 - 1/4 turn after the spark plug seats.
If installing a new spark plug, tighten 1/2 turn after the spark plug seats.
A loose spark plug can overheat and damage the engine.
Over tightening the spark plug can damage the threads in the cylinder head.
7. Attach the spark plug cap.
IDLE SPEED ADJUSTMENT
1. Start the engine outdoors, and allow it to warm up to operating temperature.
2. Move the throttle lever to its slowest position.
3. Turn the throttle stop screw to obtain the standard idle speed.
Standard idle speed: 1,800±150 rpm
THROTTLE STOP SCREW

Other manuals for LONCIN G200F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LONCIN G200F and is the answer not in the manual?

LONCIN G200F Specifications

General IconGeneral
Displacement196 cc
Compression Ratio8.5:1
Fuel SystemCarburetor
Starting SystemRecoil start
Weight16 kg
Fuel TypeUnleaded gasoline
Lubrication SystemSplash
Engine TypeForced air-cooled, 4-stroke, OHV, single cylinder
Bore x Stroke68 mm x 54 mm
Max Power6.5 HP (4.8 kW) / 3600 rpm
Ignition SystemTransistorized magneto ignition
Fuel Tank Capacity3.6 L
Oil Capacity0.6 L

Related product manuals