17
·With electric starter: (Optional kit)
Turn the engine switch to the START position and hold it there for 5 seconds or
until the engine starts.
Operating the starter motor for more than 5 seconds can damage
the motor. If the engine fails to start, release the switch and wait
10 seconds before operating the starter again.
If the speed of the starter motor drops after a period of time, it is an
indication that the battery should be recharged.
When the engine starts, allow the engine switch to return to the ON position.
5
. Turn the choke lever or push the choke rod to the OPEN position as the engine
warms up.
Stopping the engine
In an emergency:
To stop the engine in an emergency, move the engine switch to the OFF position.
In normal use:
1
. Turn the AC circuit breaker to the OFF position.
Disconnect the DC battery charging cables.
2
. Turn the engine switch to the OFF position.
3
. Turn the fuel valve to the OFF position.
7. MAINTENANCE
Good maintenance is essential for safe, economical, and trouble-free operation. It will
also help reduce air pollution.
Exhaust gas contains poisonous carbon monoxide. Shut off
the engine before performing any maintenance. If the engine
must be run, make sure the area is well ventilated.
Periodic maintenance and adjustment is necessary to keep the generator in good
operating condition. Perform the service and inspection at the intervals shown in the
Maintenance schedule below.
1) MAINTENANCE SCHEDULE