4) Air cleaner service
A dirty air cleaner will restrict air flow to the carburetor. To prevent carburetor
malfunction, service the air cleaner regularly. Service more frequently when operating
the generator in extremely dusty areas.
Using gasoline or flammable solvent to clean the filter element
can cause a fire or explosion. Use only soapy water or
nonflammable solvent.
Never run the generator without the air cleaner. Rapid engine
wear will result.
1
. Unsnap the air cleaner cover clips, remove
the air cleaner cover, and remove the element.
2
. Wash the element in a solution of household
detergent and warm water, then rinse
thoroughly; or wash in nonflammable or high
flash point solvent. Allow the element to dry
thoroughly.
3
. Soak the element in clean engine oil and
squeeze out the excess oil. The engine will
smoke during initial start-up it too much oil
is left in the element.
4
. Reinstall the air cleaner element and the cover.
bolt
AIR CLEANER COVER
ELEMENT
AIR CLEANER ELEMENT