12 Technical data
2000 Series Technical data
See page 14
Schedule calculation for the chimney
Type
Flue
PA
Flue Gas
Mass Flow
(g/s)
Flue Gas
Temperatur
e
Rate of
Efficiency %
Rated
output
kW
2060
12
6,1 m
344°
81
8
2080
12
6,1 m
344°
81
8
Wood quantity
at kindling and filling
Kindling
Wood
Wood
2,4 kg
1,9 kg
Product Fiche
Technical Specifications
Safety distance to combustible
Materials
Type
Height
mm
Width
mm
Depth
mm
Weight
kg
A*
mm
B*
mm
C*
mm
In front
of mm
2060
930
520
405
175
200
200
200
800
2080
930
520
405
267
200
200
200
800
Name or trademark
Lotus
Notes
Model identifier
2000 Series
Energy efficiency
class
A+
Direct heat output
8,0 kW
-meaning the space heat output according to the
product standard
-rounded to the nearest one decimal place
Energy efficiency
index
(EEI)
108,5
- rounded to the nearest integer:
-calculation with EEI-calculator²
Energy efficiency at
nominal heat output
81,0 %
-Efficiency at nominal heat output according to the
product
standard (rounded to the nearest one decimal place)
Specific precautions
that shall be taken
when assembling, in-
stalling or maintaining
the local space heater.
Selected examples:
- Fire protection and safety distances such as distances to combustible
building materials must be observed!
- An adequate supply of combustion air for the appliance must be
guaranteed at all times. Air-suction systems can interfere with the
combustion air supply!
Setting of register
Primary
Secondary

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lotus 2000 and is the answer not in the manual?

Lotus 2000 Specifications

General IconGeneral
CategoryWood stove
BrandLotus
Model2000
EPA certifiedYes
Log length18 inches
MaterialSteel