Maestro Series Technical Data
Schedule calculation for the chimney * See page 14
Type
Flue
PA
Flue Gas
Mass Flow
(g/s)
Flue Gas
Temperature
Rate of
Efficiency
%
Rated output
kW
Maestro 152 S
12
5,16 m
270°
83,5
6
Maestro 152 IN
12
5,16 m
270°
83,5
6
Technical Specifications
Safety distance to combustible Materials
Type
Height
mm
Width
mm
Depth
mm
Weight
kg
A*
mm
B*
mm
C*
mm
In front
of mm
Maestro 152 S
1533
560
560
510
220
100
220
800
Maestro 152 IN
1533
560
560
510
220
100
220
800
Wood quantity
at kindling and filling
Kindling Wood
Wood
2,02,5 kg
2,5 kg
Name or trademark
Lotus
Notes
Model identifier
Maestro Series
Energy efficiency class
A+
Direct heat output
6,0 kW
-meaning the space heat output according to the product
standard
-rounded to the nearest one decimal place
Energy efficiency index
(EEI)
112
- rounded to the nearest integer:
-calculation with EEI-calculato
Energy efficiency at
nominal heat output
83,5 %
-Efficiency at nominal heat output according to the product
standard (rounded to the nearest one decimal place)
Specific precautions
that shall be taken
when assembling, in-
stalling or maintaining
the local space heater.
Selected examples:
- Fire protection and safety distances such as distances to combustible building
materials must be observed!
- An adequate supply of combustion air for the appliance must be guaranteed at
all times. Air-suction systems can interfere with the combustion air supply!
Setting of register