33
Style 370 Technical Data
*See page 14
Schedule calculation for the chimney ** Se next page
Type
Flue
PA
Flue Gas
Mass Flow
(g/s)
Flue Gas
Temperature
Rate of
Efficiency %
Rated output
kW
Style 370 S
12
5,5 m
302°
77
5,8
Style 370 IN
12
5,5 m
302°
77
5,8
Style 370 LI
12
5,5 m
302°
77
5,8
Technical Specifications
Safety distance to combustible Materials
Type
Height
mm
Width
mm
Depth
mm
Weight
kg
A*
mm
B*
mm
C*
mm
In front
of mm
Style 370 S
927
718
350
145
250
250
250
1400**
Style 370 IN
927
718
350
145
250
250
250
1400**
Style 370 LI
927
718
350
143
250
250
250
1400**
Wood quantity
at kindling and filling
Kindling Wood
Wood
1,3 kg
1,4 kg
Name or trademark
Lotus
Notes
Model identifier
Style 370
Energy efficiency class
A
Direct heat output
5,8 kW
-meaning the space heat output according to the product
standard
-rounded to the nearest one decimal place
Energy efficiency index
(EEI)
103
- rounded to the nearest integer:
-calculation with EEI-calculato
Energy efficiency at
nominal heat output
77,0 %
-Efficiency at nominal heat output according to the product
standard (rounded to the nearest one decimal place)
Specific precautions
that shall be taken
when assembling, in-
stalling or maintaining
the local space heater.
Selected examples:
- Fire protection and safety distances such as distances to combustible building
materials must be observed!
- An adequate supply of combustion air for the appliance must be guaranteed at
all times. Air-suction systems can interfere with the combustion air supply!