EasyManua.ls Logo

LoveGo G2 - User Manual

LoveGo G2
10 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Let’s Go Along With Love! Let’s Go Along With Love!
G2
Portable oxygen concentrator
User Manual
Lovego, let’s go along with love
Do what you want to do
Table of contents
1. Introduction……………..….……………………………………..…….2
2. Important Safety Rules………………………….………………..…….3
3. Unpack your Lovego ……………………………….……………..……4
4. User Controls & System Status Indicators………………….....………5
5. Quick Start…………………………………………….…….…..…….6
6. How to operate………….………………….……….…....………..……7
7. How to operate with battery..………………..…………...…………....9
8. How to operate with battery....………………………………………..10
9. Important Safety Rules…………...………………..………...………...11
10. Maintenance ………….………………………………...….…..….…...13
11. Trouble shooting……………………..…………………..…….………14
12. Specification ……….........……........……….……………….....………16
13. Warranty..................................................................................................17
14. Online support........................................................................................18

Questions and Answers

  • L
    lisa82Jul 31, 2025
    Why is my LoveGo G2 Medical Equipment alarm beeping with solid green and red lights?
    • D
      Diane MyersJul 31, 2025
      If your LoveGo Medical Equipment alarm beeps and the green and red lights are solid, it means the concentrator temperature is too high, and oxygen production is shutting down. Make sure the bottom outlet vents are not blocked. If the problem continues, use a backup oxygen source and contact your equipment provider.
  • J
    Julie LangAug 4, 2025
    How to turn on LoveGo Medical Equipment if it doesn't power on?
    • M
      moorerobinAug 4, 2025
      If your LoveGo Medical Equipment is not powering on when you press the On/Off button, make sure the power switch at the bottom is turned on.
  • V
    vwilliamsAug 9, 2025
    What to do if there is no oxygen from my LoveGo Medical Equipment?
    • P
      pamela69Aug 9, 2025
      If there is no oxygen coming from your LoveGo Medical Equipment, check the cannula and its connection to the concentrator nozzle to ensure it is properly connected and not kinked or blocked.
  • K
    krobertsAug 13, 2025
    What to do if LoveGo G2 Medical Equipment alarm is beeping but the LCD display doesn’t light on?
    • C
      cruzkatieAug 13, 2025
      If the alarm on your LoveGo Medical Equipment is beeping and the LCD display isn’t lighting up, the AC power supply might not be connected correctly. Verify the power supply connection.
  • R
    Roy WatsonAug 17, 2025
    What to do if LoveGo Medical Equipment battery runs off?
    • K
      Kevin GarciaAug 17, 2025
      If your LoveGo Medical Equipment battery runs out, you should recharge the battery or use a spare battery.
  • S
    Susan HarrisAug 22, 2025
    What does it mean if the yellow light is solid on my LoveGo Medical Equipment?
    • D
      davidbarnesAug 22, 2025
      If the yellow light on your LoveGo Medical Equipment is solid, it means the concentrator is producing oxygen at a low level (less than 82%). Contact your equipment provider.
  • K
    Kimberly EvansAug 26, 2025
    What to do if the red light is solid for more than 5 minutes on LoveGo Medical Equipment?
    • A
      Austin LewisAug 26, 2025
      If the red light on your LoveGo Medical Equipment stays solid for more than 5 minutes, it means the concentrator is producing oxygen at a low level (less than 72%). Contact your equipment provider.

Summary

Important Safety Rules

Warning: Operational and Cord Safety

Check rating, keep cords from heat, do not operate if damaged or wet.

Warning: Oxygen Flammability Hazard

Avoid smoking/flames near unit, no oil/grease due to oxygen promoting rapid burning.

User Controls

Quick Start

How to Operate Your Lovego POC

Operating with Battery and in Car

Power Connection Methods

Important Safety Rules (Continued)

Danger: Electrical Shock Risk

Reduce risk of serious or fatal injury from electrical shock.

Warning: Cord and Operation Safety

Check electric rating, keep cords from heat, do not operate if damaged.

Warning: Oxygen Flammability

Device produces oxygen, avoid smoking/flames, no oil/grease near unit.

Operational Warnings and Cautions

Warning: Flammable Material Hazard

Do not leave headset under cover when unit is on; oxygen makes material flammable.

Danger: Electrical Shock Hazard (Maintenance)

Turn off unit and remove power cord before maintenance.

Maintenance Procedures

Troubleshooting Guide

Low Oxygen Purity Indicators

Address yellow (low purity <82%) or red (low purity <75%) lights and alarms.

Warranty Information

LoveGo G2 Specifications

General IconGeneral
Device TypePortable Oxygen Concentrator
Oxygen Concentration93%±3%
Oxygen Output/Flow Rate1-5 L/min
Oxygen Purity93%±3%
Sound Level≤ 45 dB(A)
Battery Charging Time4-6 hours
Power Consumption90 W
Noise Level≤ 45 dB(A)
Power SupplyAC 220V, 50Hz
Operating Temperature5°C to 40°C
AlarmsLow oxygen concentration alarm

Related product manuals