54 |
Specications | Link-9 User Guide
Specications
GENERAL
Power supply: 12 V DC battery system
Nominal operating voltage: + 13.6 V DC
Low battery alert: 10.5 V DC +/- 0.5 V
Over voltage protection: > 15.8 V +/- 0.5 V
Current drain (Transmit): ≤ 6 A @ 25 W / 1.5 A @ 1W (12 V DC)
Current drain (Receive): Less than 450 mA in standby
Replacement Fuse: 8 A, Glass type 3 AG; 32 mm (1.25”)
Temperature range: -20 ºC to +55 ºC (-4 ºF to 131 ºF)
Usable channels: International, USA, Canada, Weather
(country specific)
Mode: 16K0G3E (FM) / 16K0G2B (DSC)
DSC mode: Class D (Global) with dual receiver
(individual CH70)
Standards - EU: EN 60945:2002, EN 60950-1:2006
+A11:2009+, A1:2010+A12:2011
+A2:2013, EN 62311:2008, EN 301
843-1 V2.2.1, EN 301 843-2 V2.2.1,
EN 301 489-1 V2.1.1, EN 301 489-5
V2.2.0, EN 301 489-17 V3.1.1, EN 301
489-19 V2.1.0, EN 301 025 V2.2.1, EN
300 698 V2.2.1, EN 303 413 V1.1.1, EN
300 328 V2.1.1
Standards - US/CAN: US/CAN: FCC Part 80, RSS-Gen Issue
5, RSS-182 Issue 5, FCC Part 18
Standards - INT: AS/NZS ETSI EN 301 025
Standards - AIS: ITU-R M.1371-5
Frequency range,
- Transmitter:
- Receiver:
156.025 - 157.425 MHz
156.050 - 163.275 MHz
Channel spacing: 25 KHz
Frequency stability: ± 5 ppm
Frequency control: PLL
Software version
(at time of release):: v3.21
9