Important User Information
i
SV-iC5
Thank you for purchasing LS Variable Frequency Drives!
SAFETY INSTRUCTIONS
Always follow safety instructions to prevent accidents and potential hazards from occurring.
In this manual, safety messages are classified as follows:
WARNING
CAUTION
Throughout this manual we use the following two illustrations to make you aware of safety considerations:
Identifies potential hazards under certain conditions.
Read the message and follow the instructions carefully.
Identifies shock hazards under certain conditions.
Particular attention should be directed because dangerous voltage may be present.
Keep operating instructions handy for quick reference.
Read this manual carefully to maximize the performance of SV-iC5 series inverter and ensure its safe use.
WARNING
Do not remove the cover while power is applied or the unit is in operation.
Otherwise, electric shock could occur.
Do not run the inverter with the front cover removed.
Otherwise, you may get an electric shock due to high voltage terminals or charged capacitor
exposure.
Do not remove the cover except for periodic inspections or wiring, even if
the input power is not applied.
Otherwise, you may access the charged circuits and get an electric shock.
Wiring and periodic inspections should be performed at least 10 minutes
after disconnecting the input power and after checking the DC link voltage
is discharged with a meter (below DC 30V).
Otherwise, you may get an electric shock.
Operate the switches with dry hands.
Otherwise, you may get an electric shock.
Do not use the cable when its insulating tube is damaged.
Otherwise, you may get an electric shock.
Do not subject the cables to scratches, excessive stress, heavy loads or
pinching.
Otherwise, you may get an electric shock.
Improper operation may result in slight to medium personal injury
or property damage.
Improper operation may result in serious personal injury or death.

Table of Contents

Questions and Answers

  • B
    brookedrakeAug 15, 2025
    What to do if my LS Industrial Systems SV015iC5-1F shows overcurrent?
    • R
      Richard AvilaAug 15, 2025
      If your LS Industrial Systems Inverter displays an overcurrent error, this could be due to several reasons. First, be cautious and ensure the cause is removed before restarting to prevent IGBT damage. Possible solutions include increasing the Accel/Decel time, replacing the inverter with one of appropriate capacity if the load is too great, or, if the motor was free running, resume operation after it stops, or use H22 (Speed search) in Function group 2. Also, check the output wiring for short circuits or ground faults, and inspect the mechanical brake of the motor if it's operating too fast.
  • E
    erik44Aug 18, 2025
    Why is my LS Industrial Systems Inverter overheating?
    • B
      Blake JohnsonAug 18, 2025
      If your LS Industrial Systems Inverter's heat sink is overheating, it could be due to a few reasons. Check the cooling system for any obstructions clogging the heat sink. If the cooling fan is old, replace it with a new one. Also, ensure that the ambient temperature is under 40°C.
  • J
    Joshua BestAug 21, 2025
    What causes LS Industrial Systems SV015iC5-1F Inverter overload and how to fix it?
    • K
      Karen ButlerAug 21, 2025
      An overload in your LS Industrial Systems Inverter can occur if the load is greater than the inverter's rating, in which case you should upgrade the capacity of the motor and inverter or reduce the load weight. It may also happen if the inverter capacity is incorrectly selected, so ensure you select the correct capacity. Another possible cause is that the torque boost scale is set too high; try reducing it.
  • K
    Kyle RiggsAug 25, 2025
    What to do if my LS Industrial Systems Inverter shows low voltage?
    • A
      Amy HowellAug 25, 2025
      If your LS Industrial Systems Inverter is showing a low voltage error, check whether the line voltage is below its rating. Also, verify if a load larger than the line capacity is connected to the line, such as a welding machine or a motor with high starting current. Adjust the line capacity accordingly. Finally, inspect the magnetic switch at the input side of the inverter and change it if it's faulty.
  • C
    Christine MeadowsAug 27, 2025
    What causes ground fault current in LS Industrial Systems Inverter?
    • D
      Donald MarshAug 27, 2025
      A ground fault current in your LS Industrial Systems Inverter can be caused by a ground fault at the output wiring of the inverter, so check the wiring of the output terminal. Another cause could be damaged motor insulation due to heat, in which case you should replace the motor.
  • A
    Amanda MatthewsAug 30, 2025
    Why does my LS Industrial Systems Inverter show an over voltage error?
    • J
      Jennifer DeanAug 30, 2025
      An over voltage error on your LS Industrial Systems Inverter can occur if the deceleration time is too short compared to the GD2 of the load, so increase the deceleration time. Another cause could be a regenerative load at the inverter output, in which case you should use a Dynamic Brake Unit. Also, check whether the line voltage exceeds its rating.
  • B
    Becky HodgesSep 2, 2025
    What to do if LS Industrial Systems Inverter cooling fan is not working?
    • D
      Donna SanchezSep 2, 2025
      If the cooling fan in your LS Industrial Systems Inverter is not working, check the ventilating slot for any alien substances and remove them. If the inverter has been in use for a while, replace the cooling fan.
  • J
    Jesse MartinSep 5, 2025
    What causes output phase loss in LS Industrial Systems SV015iC5-1F Inverter?
    • C
      Carla Garcia MDSep 5, 2025
      Output phase loss in your LS Industrial Systems Inverter can result from a faulty contact of the magnetic switch at the output, so make sure the connection is secure. It can also be caused by faulty output wiring, so check the wiring.
  • R
    Roger WattsSep 8, 2025
    Why does my LS Industrial Systems SV015iC5-1F show electronic thermal error?
    • H
      hernandeznicholasSep 8, 2025
      An electronic thermal error in your LS Industrial Systems Inverter can occur if the motor has overheated, so reduce the load weight and operating duty. It may also happen if the load is greater than the inverter rating, so replace the inverter with one of higher capacity. Ensure that the ETH level is appropriately set, and select the correct inverter capacity. If the inverter has been operated at low speed for too long, install a cooling fan with a separate power supply.
  • M
    Michael GonzalesSep 12, 2025
    What does external fault A contact input mean on my LS Industrial Systems Inverter?
    • A
      Angel GuerraSep 12, 2025
      The 'External fault A contact input' error on your LS Industrial Systems Inverter indicates that the terminal set to “18 (External fault-A)” or “19 (External fault-B)” in I20-I24 in I/O group is ON. To resolve this, eliminate the cause of the fault at the circuit connected to the external fault terminal or the cause of the external fault input.

Summary

Safety Instructions

Operating Precautions

Handling and installation

Manual covers handling and installation procedures for the inverter.

Installation

Installation precautions

Important precautions to follow during inverter installation to ensure safety and proper function.

Wiring

Terminal wiring

Details on connecting power supply, motor, and control signals to the inverter terminals.

Programming Keypad

Keypad features

Description of the keypad layout, display, and buttons for inverter operation.

Basic operation

Frequency Setting and Basic Operation

Instructions on setting frequency and performing basic inverter operations.

Basic Functions

Frequency mode

Explains different modes for setting the inverter's operating frequency.

Advanced functions

DC brake

Details on configuring and using the DC brake function for stopping the motor.

PID Control

Detailed configuration of the PID control loop for process regulation.

Auto tuning

Procedure for automatically measuring motor parameters for optimal performance.

Sensorless vector control

Setup and configuration for sensorless vector control operation.

Monitoring

Operating status monitoring

How to monitor the inverter's current, RPM, and DC link voltage.

Protective functions

Electronic Thermal

Configuration of electronic thermal protection for the motor against overheating.

Troubleshooting & Maintenance

Protective functions

Information on fault displays, protective functions, and their descriptions.

Fault Remedy

Guidance on identifying causes and remedies for inverter faults.

Specifications

Technical data

Provides input/output ratings, control modes, and operation features of the inverter.

LS Industrial Systems SV015iC5-1F Specifications

General IconGeneral
BrandLS Industrial Systems
ModelSV015iC5-1F
CategoryInverter
LanguageEnglish

Related product manuals