29
XII. TROUBLESHOOTING
TROUBLESHOOTING |
FAULT
CODE
MAIN REASON SOLUTION
E01
The wire from computer to
bottom control board did not
connect well
1. Check the connection wire between computer
and control board was well connected.
2. Make sure the IC on the control board was
well inserted. If not re-insert.
3. Abnormal power supply in control board.
Please change a new control board.
E02 Protect the exploding
1. Bad contact with motor open circuit. Please
change a new motor or check the connector.
2. Power tube was punctured. Please change a
new Power tube or control board.
E05 Over current Protection
1. Overloaded.
2. Running board with heavy resistance. Need
to be oiled.
3. Damage in Motor. Change to a new motor.
E06 Motor wire connection problem
1. Check if the motor connect wire is connected
properly.
2. Check if peculiar smell comes from
controller if it is, replace the controller.
E07 Parameter missing 1. Change Control Board