EasyManua.ls Logo

LSIS SV040iG5A-4 User Manual

LSIS SV040iG5A-4
181 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image

Table of Contents

Questions and Answers:

LSIS SV040iG5A-4 Specifications

General IconGeneral
ModelSV040iG5A-4
TypeInverter
Input Frequency50/60 Hz
IP RatingIP20
Cooling MethodForced Air Cooling
Enclosure RatingIP20
Control MethodV/F Control, Sensorless Vector Control
Rated Power4.0 kW
Input Voltage380-480 V
Output Voltage0 - Input Voltage
Output Frequency0-400 Hz
Efficiency98%
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheat, Short Circuit
Operating Temperature-10 to 50°C
Storage Temperature-20°C to +65°C
Humidity5 to 95% RH (Non-condensing)
AltitudeUp to 1000 m
Communication InterfaceRS485

Summary

Safety Instructions and Precautions

WARNING and CAUTION Messages

Critical safety alerts for preventing serious injury, death, or property damage.

General Safety Precautions

Essential guidelines for safe handling, installation, and operation of the inverter.

OPERATING PRECAUTIONS

Handling, Installation, and Wiring

Guidelines for safe physical setup, mounting, environmental conditions, and electrical connections.

CHAPTER 2 - INSTALLATION & WIRING

CHAPTER 3 - BASIC CONFIGURATION

CHAPTER 4 - PROGRAMMING KEYPAD & BASIC OPERATION

Keypad Features and Navigation

Explains keypad functions, display indicators, and navigating parameter groups.

Monitoring Operation Status and Faults

How to view real-time data, fault codes, and history.

Frequency Setting Methods

Configuration for setting frequency via keypad, potentiometer, terminals, and communication.

CHAPTER 7 - BASIC FUNCTIONS

Operating Command Setting Methods

Methods for controlling inverter operation using keypad, terminals, or communication.

Accel/Decel Time and Pattern Settings

How to set acceleration, deceleration times, and curve patterns.

V/F Control Patterns and Torque Boost

Methods for controlling motor voltage/frequency and configuring torque boost.

Stop Method Selection

Options for how the inverter stops the motor: Decel, DC Braking, Free Run.

Frequency Limit Settings

Setting operational frequency limits using Max/Start frequencies and command limits.

CHAPTER 8 - ADVANCED FUNCTIONS

PID Control Configuration

Setting up proportional-integral-derivative control loops for process automation.

Auto-tuning Procedure

Procedure for automatically measuring motor parameters for optimal performance.

Sensorless Vector Control Setup

Configuring the inverter for sensorless vector control of the motor.

CHAPTER 9 - MONITORING

Fault Condition Monitoring and History

How to view current faults, historical data, and diagnostic information.

CHAPTER 10 - PROTECTIVE FUNCTIONS

Electronic Thermal and Overload Protection

Settings for motor thermal overload and overload warning/trip protection.

CHAPTER 11 - RS485 COMMUNICATION

CHAPTER 12 - TROUBLESHOOTING & MAINTENANCE

Fault Remedy Guide

Troubleshooting steps for common inverter fault codes and causes.

Related product manuals