EasyManua.ls Logo

LTM E 500 - Dimensions and Connections; Energy Consumption Data; 14 Specification

LTM E 500
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
INSTALLATION
Specification
E 500-3000 | 23
ENGLISH
14. Specification
14.1 Dimensions and connections
b01
a20
450
100
256
i13
D0000068095
E 500 E 750 E 1000 E 1500 E 2000 E 2500 E 3000
a20 Appliance Width mm 348 426 426 582 738 894 1050
i13 Wall mounting bracket Horizontal hole spacing mm 101 179 179 335 491 647 803
b01 Entry electrical cables
14.2 Energy consumption data
The product data complies with EU regulations relating to the Directive on the ecodesign of energy related products (ErP).
E 500 E 750 E 1000 E 1500 E 2000 E 2500 E 3000
200247 200248 200249 200250 200251 200252 200253
Manufacturer LTM LTM LTM LTM LTM LTM LTM
Heating output
Rated heating output P
nom
kW 0.5 0.8 1.0 1.5 2.0 2.5 3.0
Minimum heating output (standard value) P
min
kW 0.0 0.0 0.0 0.0 0.0 0.0 0.0
Maximum continuous heating output P
max,c
kW 0.5 0.8 1.0 1.5 2.0 2.5 3.0
Auxiliary power consumption
At rated heating output el
max
kW 0.000 0.000 0.000 0.000 0.000 0.000 0.000
At minimum heating output el
min
kW 0.000 0.000 0.000 0.000 0.000 0.000 0.000
In standby el
SB
kW 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Type of heating output/room temperature control
Single stage heating output, no room temperature control - - - - - - -
Two or more manually selectable stages, no room temperature
control
- - - - - - -
Room temperature control with mechanical thermostat - - - - - - -
With electronic room temperature control - - - - - - -
Electronic room temperature control and time of day control - - - - - - -
Electronic room temperature control and day of week control x x x x x x x
Other control options
Room temperature control with presence detection - - - - - - -
Room temperature control with window open detection x x x x x x x
With remote control option - - - - - - -
With adaptive control of heating start x x x x x x x
With operating time limitation - - - - - - -
With black bulb sensor - - - - - - -

Table of Contents