EasyManua.ls Logo

Lubing Top Climate System - Electrical Connections; Before First Climate Operation

Default Icon
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Montage Installation
LUBING Top Klima System - 19 - LUBING Top Climate System
Pressure relieve
To prevent spraying under low pressure it is im-
portant to relieve the pressure of the nozzle
lines. An electrical pressure relieve valve direct-
ly at the pump unit or a mechanical valve at the
end of each pipe is doing this work.
The operating time of the electrical pressure re-
lieve valve should be 2 sec. For draining the
nozzle lines it is possible to increase the operat-
ing time (see user manual controller).
House soaking
It’s possible to soak the house with the System.
Therefor switch on the function Wetting“ on the
Big Dutchman Controller.
Important: Take care, that the nozzle lines are
free of impurity and dirt. So you guaranty a per-
fect operation of the nozzles.
Fixing of the nozzles:
Important! Before mounting the nozzles it is
essential to clean the nozzle lines. Be sure,
that the plant is completely free of all kind of
mounting- and transport soil.
Screw in the nozzles handtight (1 1.5 Nm).
While srewing in the adapter check also the cor-
rect seat of the nozzle heads.
Electrical connections:
Works on the electrical equipment may only be
carried out by a skilled electrician in accordance
with the applicable savety rules and the operat-
ing instruction. You'll find the clamping drawing
at the end of the operating instruction (page 47).
Before the first climate operation
Take care that before the complete starting the
mechanical drain valves are screwed out or all
mechanical valves are opened.
After that set the pump for 2 minutes at work. So
you can clean the mounted nozzle lines again
and remove the last impurities.
After the cleaning session close the ballvalves
at the end of each pipe. Screw in the mechani-
cal drain valves and fit them with ¾“-tubes and
clips. Take care, that the drained water flows
outside of the house